FabDigitFabDigit

Stainless Steel 1.6982-A vs 1.6982-F

Stainless Steel · 1.6982 temper comparison

1.6982-A and 1.6982-F are two conditions of the same stainless steel grade, 1.6982: A (solution annealed) versus F (as fabricated). The chemistry is identical, so every difference below comes from the condition. 1.6982-F is the stronger of the two: yield strength 850 MPa (123 ksi) against 520 MPa (75.4 ksi) for 1.6982-A, about 63% more; tensile strength follows at 1,100 MPa (160 ksi) vs 720 MPa (104 ksi). In exchange, 1.6982-A is the more ductile: elongation 22% versus 7% for 1.6982-F, and 1.6982-F is harder (400 HB vs 210 HB). 1.6982-A runs hotter in service (450°C vs 300°C continuous). On the shop floor, 1.6982-A machines more easily (fair vs poor) and 1.6982-A welds better (very good vs fair).

1.6982-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.6982-FChoose it when strength drives the design.

1.6982-A vs 1.6982-F: properties

1.6982-A1.6982-F

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
1,100 MPa160 ksi

Yield Strength (0.2% offset)

520 MPa75.4 ksi
850 MPa123 ksi

Elongation at Break

22%
7%

Reduction in Area

62%
25%

Compressive Strength

650 MPa94.3 ksi
870 MPa126 ksi

Shear Strength

500 MPa72.5 ksi
660 MPa95.7 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
430 MPa62.4 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

130 J95.9 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

210 HB
400 HB

Hardness, Rockwell C

18 HRC
42 HRC

Hardness, Vickers

220 HV
415 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

25 W/m·K14.4 BTU/hr·ft·°F
24 W/m·K13.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

450°C842 °F
300°C572 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.9 % IACS
2.8 % IACS

Electrical Resistivity

6×10⁻⁷ Ω·m23.6 µΩ·in
6.2×10⁻⁷ Ω·m24.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
20%

Weldability

75 / 100
40 / 100

Formability (cold)

15 / 100
5 / 100

Same in both: Castability 68 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 36 MJ/kg15,477 BTU/lb · Embodied Carbon (primary production) 2.8 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.6982

1.6982-A vs 1.6982-F — frequently asked

Is 1.6982-F stronger than 1.6982-A?

Yes. 1.6982-F has a typical yield strength of 850 MPa (123 ksi) against 520 MPa (75.4 ksi) for 1.6982-A — about 63% more. Tensile strength is 1,100 MPa (160 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, A or F?

QT1 is the default 1.6982 condition in the FabDigit quote flow (neither A nor F). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.6982-A or 1.6982-F?

1.6982-A. Its machinability rates fair (50/100) against poor (20/100) for 1.6982-F; for welding the order is 1.6982-A first (very good, 75/100) then 1.6982-F (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.6982-A and 1.6982-F side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.