FabDigitFabDigit

Stainless Steel 1.4886 Annealed vs 1.4886-CD

Stainless Steel · 1.4886 temper comparison

1.4886 Annealed and 1.4886-CD are two conditions of the same stainless steel grade, 1.4886: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4886-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 1.4886 Annealed, about 73% more; tensile strength follows at 690 MPa (100 ksi) vs 585 MPa (84.8 ksi). In exchange, 1.4886 Annealed is the more ductile: elongation 43% versus 30% for 1.4886-CD, and 1.4886-CD is harder (200 HB vs 160 HB).

1.4886 AnnealedChoose it when the part is bent, formed or impact-loaded.

1.4886-CDChoose it when strength drives the design.

1.4886 Annealed vs 1.4886-CD: properties

1.4886 Annealed1.4886-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
450 MPa65.3 ksi

Elongation at Break

43%
30%

Reduction in Area

58%
45%

Shear Strength

400 MPa58 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
285 MPa41.3 ksi

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

160 HB
200 HB

Hardness, Rockwell B

80 HRB
92 HRB

Same in both: Elastic (Young's) Modulus 196 GPa28.4 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.94 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,371°C2,500 °F · Liquidus Temperature 1,427°C2,601 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.9 µm/m·K8.3 µin/in·°F · Max Service Temperature (continuous) 1,150°C2,102 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

75 / 100
70 / 100

Formability (cold)

65 / 100
40 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 110 MJ/kg47,292 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4886

1.4886 Annealed vs 1.4886-CD — frequently asked

Is 1.4886-CD stronger than 1.4886 Annealed?

Yes. 1.4886-CD has a typical yield strength of 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 1.4886 Annealed — about 73% more. Tensile strength is 690 MPa (100 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default 1.4886 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1.4886 Annealed or 1.4886-CD?

1.4886 Annealed. Its weldability rates very good (75/100) against very good (70/100) for 1.4886-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4886 Annealed and 1.4886-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.