FabDigitFabDigit

Stainless Steel 1.4520 1/4H vs 1.4520-CD

Stainless Steel · 1.4520 temper comparison

1.4520 1/4H and 1.4520-CD are two conditions of the same stainless steel grade, 1.4520: 1/4H (quarter hard) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4520-CD is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 450 MPa (65.3 ksi) for 1.4520 1/4H, about 7% more; tensile strength follows at 580 MPa (84.1 ksi) vs 550 MPa (79.8 ksi). 1.4520-CD is the more ductile: elongation 14% versus 12% for 1.4520 1/4H, and 1.4520-CD is harder (220 HV vs 208 HV).

1.4520-CDChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1.4520 1/4H vs 1.4520-CD: properties

1.4520 1/4H1.4520-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
580 MPa84.1 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
480 MPa69.6 ksi

Elongation at Break

12%
14%

Reduction in Area

65%
50%

Shear Strength

340 MPa49.3 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

270 MPa39.2 ksi
285 MPa41.3 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

200 HB
210 HB

Hardness, Rockwell B

92 HRB
95 HRB

Hardness, Vickers

208 HV
220 HV

Same in both: Elastic (Young's) Modulus 220 GPa31.9 Msi · Shear Modulus 85 GPa12.3 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 25 W/m·K14.4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
54 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
59 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
62%

Formability (cold)

50 / 100
45 / 100

Same in both: Weldability 78 / 100 · Brazeability / Solderability 60 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 40 MJ/kg17,197 BTU/lb · Embodied Carbon (primary production) 3 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4520

1.4520 1/4H vs 1.4520-CD — frequently asked

Is 1.4520-CD stronger than 1.4520 1/4H?

Yes. 1.4520-CD has a typical yield strength of 480 MPa (69.6 ksi) against 450 MPa (65.3 ksi) for 1.4520 1/4H — about 7% more. Tensile strength is 580 MPa (84.1 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, 1/4H or CD?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 1.4520 1/4H over 1.4520-CD?

Pick 1.4520-CD when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4520 1/4H and 1.4520-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.