FabDigitFabDigit

Stainless Steel 1.4477-CD vs 1.4477 CR+A

Stainless Steel · 1.4477 temper comparison

1.4477-CD and 1.4477 CR+A are two conditions of the same stainless steel grade, 1.4477: CD (cold drawn) versus CR+A (cold Rolled + Solution Annealed, pickled). The chemistry is identical, so every difference below comes from the condition. 1.4477-CD is the stronger of the two: yield strength 830 MPa (120 ksi) against 720 MPa (104 ksi) for 1.4477 CR+A, about 15% more; tensile strength follows at 980 MPa (142 ksi) vs 900 MPa (131 ksi). In exchange, 1.4477 CR+A is the more ductile: elongation 30% versus 20% for 1.4477-CD, and 1.4477-CD is harder (310 HB vs 280 HB).

1.4477-CDChoose it when strength drives the design.

1.4477 CR+AChoose it when the part is bent, formed or impact-loaded.

1.4477-CD vs 1.4477 CR+A: properties

1.4477-CD1.4477 CR+A

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

980 MPa142 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

830 MPa120 ksi
720 MPa104 ksi

Elongation at Break

20%
30%

Reduction in Area

48%
60%

Compressive Strength

830 MPa120 ksi
700 MPa102 ksi

Shear Strength

590 MPa85.6 ksi
530 MPa76.9 ksi

Fatigue Strength (Endurance Limit)

440 MPa63.8 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

100 MPa·√m91 ksi·√in
130 MPa·√m118 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

310 HB
280 HB

Hardness, Rockwell C

32 HRC
28 HRC

Hardness, Vickers

325 HV
295 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 162 GPa23.5 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,350°C2,462 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

280°C536 °F
300°C572 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.5 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2 % IACS · Electrical Resistivity 8.5×10⁻⁷ Ω·m33.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
89 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
24 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
18%

Weldability

60 / 100
65 / 100

Formability (cold)

30 / 100
45 / 100

Polishability

75 / 100
80 / 100

Same in both: Brazeability / Solderability 30 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4477

1.4477-CD vs 1.4477 CR+A — frequently asked

Is 1.4477-CD stronger than 1.4477 CR+A?

Yes. 1.4477-CD has a typical yield strength of 830 MPa (120 ksi) against 720 MPa (104 ksi) for 1.4477 CR+A — about 15% more. Tensile strength is 980 MPa (142 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, CD or CR+A?

HR+A is the default 1.4477 condition in the FabDigit quote flow (neither CD nor CR+A). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1.4477-CD or 1.4477 CR+A?

1.4477 CR+A. Its weldability rates good (65/100) against good (60/100) for 1.4477-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4477-CD and 1.4477 CR+A side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.