FabDigitFabDigit

Stainless Steel 1.4422 +A vs 1.4422 +QT1000

Stainless Steel · 1.4422 temper comparison

1.4422 +A and 1.4422 +QT1000 are two conditions of the same stainless steel grade, 1.4422: +A (annealed) versus +QT1000 (quenched and low-temperature tempered, Rm ≥1000 MPa). The chemistry is identical, so every difference below comes from the condition. 1.4422 +QT1000 is the stronger of the two: yield strength 880 MPa (128 ksi) against 600 MPa (87 ksi) for 1.4422 +A, about 47% more; tensile strength follows at 1,070 MPa (155 ksi) vs 800 MPa (116 ksi). In exchange, 1.4422 +A is the more ductile: elongation 20% versus 15% for 1.4422 +QT1000, and 1.4422 +QT1000 is harder (330 HB vs 255 HB). 1.4422 +A runs hotter in service (300°C vs 250°C continuous). On the shop floor, 1.4422 +A machines more easily (fair vs poor).

1.4422 +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4422 +QT1000Choose it when strength drives the design.

1.4422 +A vs 1.4422 +QT1000: properties

1.4422 +A1.4422 +QT1000

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
1,070 MPa155 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
880 MPa128 ksi

Elongation at Break

20%
15%

Reduction in Area

68%
55%

Compressive Strength

620 MPa89.9 ksi
900 MPa131 ksi

Shear Strength

480 MPa69.6 ksi
645 MPa93.5 ksi

Fatigue Strength (Endurance Limit)

355 MPa51.5 ksi
460 MPa66.7 ksi

Fracture Toughness (K_IC)

135 MPa·√m123 ksi·√in
90 MPa·√m81.9 ksi·√in

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

255 HB
330 HB

Hardness, Rockwell C

24 HRC
35 HRC

Hardness, Vickers

265 HV
345 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
250°C482 °F

Same in both: Thermal Conductivity 15.5 W/m·K9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.3 % IACS · Electrical Resistivity 7.5×10⁻⁷ Ω·m29.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

48%
35%

Weldability

78 / 100
70 / 100

Formability (cold)

45 / 100
28 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 45 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 5.4 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4422

1.4422 +A vs 1.4422 +QT1000 — frequently asked

Is 1.4422 +QT1000 stronger than 1.4422 +A?

Yes. 1.4422 +QT1000 has a typical yield strength of 880 MPa (128 ksi) against 600 MPa (87 ksi) for 1.4422 +A — about 47% more. Tensile strength is 1,070 MPa (155 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, +A or +QT1000?

+QT900 is the default 1.4422 condition in the FabDigit quote flow (neither +A nor +QT1000). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4422 +A or 1.4422 +QT1000?

1.4422 +A. Its machinability rates fair (45/100) against poor (33/100) for 1.4422 +QT1000; for welding the order is 1.4422 +A first (very good, 78/100) then 1.4422 +QT1000 (very good, 70/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4422 +A and 1.4422 +QT1000 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.