FabDigitFabDigit

Stainless Steel 1.4418 +A vs 1.4418 +QT760

Stainless Steel · 1.4418 temper comparison

1.4418 +A and 1.4418 +QT760 are two conditions of the same stainless steel grade, 1.4418: +A (annealed) versus +QT760 (quenched and tempered, Rm 760–960 MPa). The chemistry is identical, so every difference below comes from the condition. 1.4418 +QT760 is the stronger of the two: tensile strength 850 MPa (123 ksi) against 800 MPa (116 ksi) for 1.4418 +A, about 6% more.

1.4418 +QT760Choose it when strength drives the design.

1.4418 +A vs 1.4418 +QT760: properties

1.4418 +A1.4418 +QT760

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
850 MPa123 ksi

Yield Strength (0.2% offset)

600 MPa87 ksi
620 MPa89.9 ksi

Shear Strength

590 MPa85.6 ksi
510 MPa74 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
375 MPa54.4 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

260 HB
255 HB

Hardness, Rockwell C

25 HRC
24 HRC

Hardness, Vickers

272 HV
268 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 166 GPa24.1 Msi · Poisson's Ratio 0.3 · Elongation at Break 20% · Reduction in Area 62% · Compressive Strength 790 MPa115 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
42%

Formability (cold)

35 / 100
28 / 100

Same in both: Weldability 72 / 100 · Castability 60 / 100 · Brazeability / Solderability 40 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4418

1.4418 +A vs 1.4418 +QT760 — frequently asked

Is 1.4418 +QT760 stronger than 1.4418 +A?

Yes. 1.4418 +QT760 has a typical tensile strength of 850 MPa (123 ksi) against 800 MPa (116 ksi) for 1.4418 +A — about 6% more.

Which condition does FabDigit quote by default, +A or +QT760?

+QT900 is the default 1.4418 condition in the FabDigit quote flow (neither +A nor +QT760). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1.4418 +A over 1.4418 +QT760?

Pick 1.4418 +QT760 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4418 +A and 1.4418 +QT760 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.