FabDigitFabDigit

Stainless Steel 1.4122 +A vs 1.4122 +QT800

Stainless Steel · 1.4122 temper comparison

1.4122 +A and 1.4122 +QT800 are two conditions of the same stainless steel grade, 1.4122: +A (annealed) versus +QT800 (quenched and tempered, Rm 800–1000 MPa). The chemistry is identical, so every difference below comes from the condition. 1.4122 +QT800 is the stronger of the two: yield strength 680 MPa (98.6 ksi) against 460 MPa (66.7 ksi) for 1.4122 +A, about 48% more; tensile strength follows at 900 MPa (131 ksi) vs 780 MPa (113 ksi). In exchange, 1.4122 +A is the more ductile: elongation 18% versus 12% for 1.4122 +QT800, and 1.4122 +QT800 is harder (285 HB vs 240 HB). On the shop floor, 1.4122 +A machines more easily (fair vs poor).

1.4122 +AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

1.4122 +QT800Choose it when strength drives the design.

1.4122 +A vs 1.4122 +QT800: properties

1.4122 +A1.4122 +QT800

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

780 MPa113 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

460 MPa66.7 ksi
680 MPa98.6 ksi

Elongation at Break

18%
12%

Reduction in Area

45%
35%

Compressive Strength

470 MPa68.2 ksi
700 MPa102 ksi

Shear Strength

470 MPa68.2 ksi
540 MPa78.3 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
420 MPa60.9 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

240 HB
285 HB

Hardness, Rockwell C

22 HRC
30 HRC

Hardness, Vickers

250 HV
300 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 163 GPa23.6 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

30 W/m·K17.3 BTU/hr·ft·°F
29 W/m·K16.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

32 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
30%

Weldability

22 / 100
15 / 100

Formability (cold)

30 / 100
12 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4122

1.4122 +A vs 1.4122 +QT800 — frequently asked

Is 1.4122 +QT800 stronger than 1.4122 +A?

Yes. 1.4122 +QT800 has a typical yield strength of 680 MPa (98.6 ksi) against 460 MPa (66.7 ksi) for 1.4122 +A — about 48% more. Tensile strength is 900 MPa (131 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, +A or +QT800?

+A is the default 1.4122 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4122 +A or 1.4122 +QT800?

1.4122 +A. Its machinability rates fair (45/100) against poor (30/100) for 1.4122 +QT800; for welding the order is 1.4122 +A first (poor, 22/100) then 1.4122 +QT800 (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4122 +A and 1.4122 +QT800 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.