FabDigitFabDigit

Stainless Steel 1.4031 +C vs 1.4031 H+T200

Stainless Steel · 1.4031 temper comparison

1.4031 +C and 1.4031 H+T200 are two conditions of the same stainless steel grade, 1.4031: +C (cold drawn) versus H+T200 (hardened ~1030 °C, oil/air quenched, tempered 150–200 °C). The chemistry is identical, so every difference below comes from the condition. 1.4031 H+T200 is the stronger of the two: yield strength 1,550 MPa (225 ksi) against 700 MPa (102 ksi) for 1.4031 +C, about 121% more; tensile strength follows at 1,900 MPa (276 ksi) vs 900 MPa (131 ksi). In exchange, 1.4031 +C is the more ductile: elongation 10% versus 2% for 1.4031 H+T200, and 1.4031 +C is harder (270 HB vs 220 HB). 1.4031 +C runs hotter in service (300°C vs 200°C continuous). On the shop floor, 1.4031 +C machines more easily (fair vs not recommended) and 1.4031 +C welds better (poor vs not recommended).

1.4031 +CChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4031 H+T200Choose it when strength drives the design.

1.4031 +C vs 1.4031 H+T200: properties

1.4031 +C1.4031 H+T200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

900 MPa131 ksi
1,900 MPa276 ksi

Yield Strength (0.2% offset)

700 MPa102 ksi
1,550 MPa225 ksi

Elongation at Break

10%
2%

Reduction in Area

35%
5%

Compressive Strength

900 MPa131 ksi
2,100 MPa305 ksi

Shear Strength

540 MPa78.3 ksi
460 MPa66.7 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
620 MPa89.9 ksi

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

270 HB
220 HB

Hardness, Vickers

285 HV
610 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Rockwell B 97 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.5 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.1 % IACS · Electrical Resistivity 5.5×10⁻⁷ Ω·m21.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
10 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
10%

Weldability

20 / 100
5 / 100

Formability (cold)

20 / 100
3 / 100

Polishability

85 / 100
90 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4031

1.4031 +C vs 1.4031 H+T200 — frequently asked

Is 1.4031 H+T200 stronger than 1.4031 +C?

Yes. 1.4031 H+T200 has a typical yield strength of 1,550 MPa (225 ksi) against 700 MPa (102 ksi) for 1.4031 +C — about 121% more. Tensile strength is 1,900 MPa (276 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, +C or H+T200?

+A is the default 1.4031 condition in the FabDigit quote flow (neither +C nor H+T200). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4031 +C or 1.4031 H+T200?

1.4031 +C. Its machinability rates fair (50/100) against not recommended (10/100) for 1.4031 H+T200; for welding the order is 1.4031 +C first (poor, 20/100) then 1.4031 H+T200 (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4031 +C and 1.4031 H+T200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.