FabDigitFabDigit

Stainless Steel 1.3955-AC vs 1.3955-ST

Stainless Steel · 1.3955 temper comparison

1.3955-AC and 1.3955-ST are two conditions of the same stainless steel grade, 1.3955: AC (spheroidize annealed) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. Both yield at about 250 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (spheroidize annealed versus solution annealed). 1.3955-ST is the more ductile: elongation 50% versus 30% for 1.3955-AC, and 1.3955-AC is harder (155 HB vs 140 HB). 1.3955-ST runs hotter in service (760°C vs 600°C continuous). On the shop floor, 1.3955-ST welds better (very good vs good).

1.3955-STChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.3955-AC vs 1.3955-ST: properties

1.3955-AC1.3955-ST

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
255 MPa37 ksi

Elongation at Break

30%
50%

Reduction in Area

35%
60%

Compressive Strength

250 MPa36.3 ksi
255 MPa37 ksi

Shear Strength

365 MPa52.9 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
210 MPa30.5 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
200 MPa·√m182 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
110 J81.1 ft·lbf

Hardness, Brinell

155 HB
140 HB

Hardness, Rockwell B

83 HRB
77 HRB

Hardness, Vickers

165 HV
150 HV

Same in both: Elastic (Young's) Modulus 193 GPa28 Msi · Shear Modulus 75 GPa10.9 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.75 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

16 W/m·K9.2 BTU/hr·ft·°F
16.2 W/m·K9.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

600°C1,112 °F
760°C1,400 °F

Same in both: Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.3 µm/m·K9.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

7.5×10⁻⁷ Ω·m29.5 µΩ·in
7.4×10⁻⁷ Ω·m29.1 µΩ·in

Same in both: Electrical Conductivity 2.3 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

48 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
40%

Weldability

62 / 100
75 / 100

Formability (cold)

15 / 100
25 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.3955

1.3955-AC vs 1.3955-ST — frequently asked

What is the difference between 1.3955-AC and 1.3955-ST?

1.3955-AC and 1.3955-ST are two conditions of the same stainless steel grade, 1.3955: AC (spheroidize annealed) versus ST (solution annealed). The chemistry is identical, so every difference below comes from the condition. Both yield at about 250 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (spheroidize annealed versus solution annealed).

Which condition does FabDigit quote by default, AC or ST?

ST is the default 1.3955 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1.3955-AC or 1.3955-ST?

1.3955-ST. Its weldability rates very good (75/100) against good (62/100) for 1.3955-AC.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.3955-AC and 1.3955-ST side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.