FabDigitFabDigit

Solder & Low-Melting Alloy Tellurium Lead Cold Worked vs Tellurium Lead-F

Solder & Low-Melting Alloy · Tellurium Lead temper comparison

Tellurium Lead Cold Worked and Tellurium Lead-F are two conditions of the same solder & low-melting alloy grade, Tellurium Lead: Cold Worked versus F (as fabricated). The chemistry is identical, so every difference below comes from the condition. Tellurium Lead Cold Worked is the stronger of the two: yield strength 16 MPa (2.32 ksi) against 8 MPa (1.16 ksi) for Tellurium Lead-F, about 100% more; tensile strength follows at 28 MPa (4.06 ksi) vs 19 MPa (2.76 ksi). In exchange, Tellurium Lead-F is the more ductile: elongation 30% versus 25% for Tellurium Lead Cold Worked, and Tellurium Lead Cold Worked is harder (7 HB vs 5 HB). Tellurium Lead-F runs hotter in service (110°C vs 90°C continuous).

Tellurium Lead Cold WorkedChoose it when strength drives the design.

Tellurium Lead-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Tellurium Lead Cold Worked vs Tellurium Lead-F: properties

Tellurium Lead Cold WorkedTellurium Lead-F

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

14.5 GPa2.1 Msi
14 GPa2 Msi

Tensile Strength (Ultimate)

28 MPa4.1 ksi
19 MPa2.8 ksi

Yield Strength (0.2% offset)

16 MPa2.3 ksi
8 MPa1.2 ksi

Elongation at Break

25%
30%

Shear Strength

18 MPa2.6 ksi
12 MPa1.7 ksi

Fatigue Strength (Endurance Limit)

8 MPa1.2 ksi
5 MPa0.73 ksi

Hardness, Brinell

7 HB
5 HB

Same in both: Shear Modulus 5.4 GPa0.78 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.43

Physical

Density and transition temperatures.

Same in both: Density 11.34 g/cm³0.41 lb/in³ · Melting Point (Solidus) 327°C621 °F · Liquidus Temperature 328°C622 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

90°C194 °F
110°C230 °F

Same in both: Thermal Conductivity 34 W/m·K19.6 BTU/hr·ft·°F · Specific Heat Capacity 129 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 29.3 µm/m·K16.3 µin/in·°F · Latent Heat of Fusion 23 J/g9.9 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.7 % IACS · Electrical Resistivity 2.24×10⁻⁷ Ω·m8.82 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.53 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
60 / 100

Formability (cold)

70 / 100
85 / 100

Same in both: Weldability 70 / 100 · Castability 85 / 100 · Brazeability / Solderability 90 / 100 · Polishability 20 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 26 MJ/kg11,178 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every solder & low-melting alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

125102050891011Density (g/cm³)Yield strength (MPa) — log scaleTellurium Lead

Tellurium Lead Cold Worked vs Tellurium Lead-F — frequently asked

Is Tellurium Lead Cold Worked stronger than Tellurium Lead-F?

Yes. Tellurium Lead Cold Worked has a typical yield strength of 16 MPa (2.32 ksi) against 8 MPa (1.16 ksi) for Tellurium Lead-F — about 100% more. Tensile strength is 28 MPa (4.06 ksi) vs 19 MPa (2.76 ksi).

Which condition does FabDigit quote by default, Cold Worked or F?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose Tellurium Lead Cold Worked over Tellurium Lead-F?

Pick Tellurium Lead Cold Worked when strength drives the design. Pick Tellurium Lead-F when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Tellurium Lead Cold Worked and Tellurium Lead-F side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.