S-200F-HIP and S-200F-SR are two conditions of the same refractory metal grade, S-200F: HIP (hot isostatic pressed) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. S-200F-HIP is the stronger of the two: yield strength 296 MPa (42.9 ksi) against 200 MPa (29 ksi) for S-200F-SR, about 48% more; tensile strength follows at 414 MPa (60 ksi) vs 330 MPa (47.9 ksi). In exchange, S-200F-SR is the more ductile: elongation 4% versus 3.5% for S-200F-HIP, and S-200F-HIP is harder (165 HB vs 140 HB).

S-200F-HIPChoose it when strength drives the design.

S-200F-SRChoose it when the part is bent, formed or impact-loaded.

S-200F-HIP vs S-200F-SR: properties

S-200F-HIPS-200F-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

414 MPa60 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

296 MPa42.9 ksi
200 MPa29 ksi

Elongation at Break

3.5%
4%

Reduction in Area

3%
3%

Compressive Strength

310 MPa45 ksi
250 MPa36.3 ksi

Shear Strength

210 MPa30.5 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
155 MPa22.5 ksi

Charpy V-Notch Impact (RT)

2 J1.2 ft·lbf
2 J1.3 ft·lbf

Hardness, Brinell

165 HB
140 HB

Hardness, Rockwell B

85 HRB
75 HRB

Hardness, Vickers

180 HV
150 HV

Same in both: Elastic (Young's) Modulus 303 GPa43.9 Msi · Shear Modulus 142 GPa20.6 Msi · Bulk Modulus 116 GPa16.8 Msi · Poisson's Ratio 0.08 · Fracture Toughness (K_IC) 12 MPa·√m10.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 1.85 g/cm³0.07 lb/in³ · Melting Point (Solidus) 1,287°C2,349 °F · Liquidus Temperature 1,290°C2,354 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

216 W/m·K125 BTU/hr·ft·°F
218 W/m·K126 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 1,925 J/kg·K0.46 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.3 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 1,350 J/g580 BTU/lb · Max Service Temperature (continuous) 500°C932 °F · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
41 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.9 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
33%

Weldability

20 / 100
22 / 100

Formability (cold)

10 / 100
15 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,400 MJ/kg601,892 BTU/lb · Embodied Carbon (primary production) 90 kg CO₂/kg · Embodied Water 2,500 L/kg300 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every refractory metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1502003005007001,0001,5005101520Density (g/cm³)Yield strength (MPa) — log scaleS-200F

S-200F-HIP vs S-200F-SR — frequently asked

Is S-200F-HIP stronger than S-200F-SR?

Yes. S-200F-HIP has a typical yield strength of 296 MPa (42.9 ksi) against 200 MPa (29 ksi) for S-200F-SR — about 48% more. Tensile strength is 414 MPa (60 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, HIP or SR?

HP is the default S-200F condition in the FabDigit quote flow (neither HIP nor SR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, S-200F-HIP or S-200F-SR?

S-200F-SR. Its machinability rates fair (38/100) against poor (33/100) for S-200F-HIP.

Ready to make it?

Upload a CAD file and FabDigit prices the part in S-200F-HIP and S-200F-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.