FabDigitFabDigit

Precious Metal Pt95Co5-H01 vs Pt95Co5-H02

Precious Metal · Pt95Co5 temper comparison

Pt95Co5-H01 and Pt95Co5-H02 are two conditions of the same precious metal grade, Pt95Co5: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. Pt95Co5-H02 is the stronger of the two: yield strength 520 MPa (75.4 ksi) against 400 MPa (58 ksi) for Pt95Co5-H01, about 30% more; tensile strength follows at 640 MPa (92.8 ksi) vs 550 MPa (79.8 ksi). In exchange, Pt95Co5-H01 is the more ductile: elongation 15% versus 8% for Pt95Co5-H02, and Pt95Co5-H02 is harder (180 HB vs 152 HB). Pt95Co5-H01 runs hotter in service (400°C vs 350°C continuous).

Pt95Co5-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Pt95Co5-H02Choose it when strength drives the design.

Pt95Co5-H01 vs Pt95Co5-H02: properties

Pt95Co5-H01Pt95Co5-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
520 MPa75.4 ksi

Elongation at Break

15%
8%

Reduction in Area

30%
18%

Shear Strength

340 MPa49.3 ksi
390 MPa56.6 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

38 J28 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

152 HB
180 HB

Hardness, Rockwell B

82 HRB
90 HRB

Hardness, Vickers

160 HV
190 HV

Same in both: Elastic (Young's) Modulus 172 GPa24.9 Msi · Shear Modulus 62 GPa9 Msi · Bulk Modulus 240 GPa34.8 Msi · Poisson's Ratio 0.39

Physical

Density and transition temperatures.

Same in both: Density 20 g/cm³0.72 lb/in³ · Melting Point (Solidus) 1,745°C3,173 °F · Liquidus Temperature 1,765°C3,209 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Thermal Conductivity 34 W/m·K19.6 BTU/hr·ft·°F · Specific Heat Capacity 135 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9.2 µm/m·K5.1 µin/in·°F · Latent Heat of Fusion 110 J/g47.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.8 % IACS · Electrical Resistivity 2.55×10⁻⁷ Ω·m10 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.25 V · Corrosion Resistance 96 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
25%

Weldability

80 / 100
75 / 100

Formability (cold)

65 / 100
45 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 250,000 MJ/kg1.07×10⁸ BTU/lb · Embodied Carbon (primary production) 13,000 kg CO₂/kg · Embodied Water 250,000 L/kg29,957 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scalePt95Co5

Pt95Co5-H01 vs Pt95Co5-H02 — frequently asked

Is Pt95Co5-H02 stronger than Pt95Co5-H01?

Yes. Pt95Co5-H02 has a typical yield strength of 520 MPa (75.4 ksi) against 400 MPa (58 ksi) for Pt95Co5-H01 — about 30% more. Tensile strength is 640 MPa (92.8 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, H01 or H02?

AC is the default Pt95Co5 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Pt95Co5-H01 or Pt95Co5-H02?

Pt95Co5-H02, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for Pt95Co5-H01; for welding the order is Pt95Co5-H01 first (very good, 80/100) then Pt95Co5-H02 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Pt95Co5-H01 and Pt95Co5-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.