FabDigitFabDigit

Precious Metal Pt95Co5-ANN vs Pt95Co5-H04

Precious Metal · Pt95Co5 temper comparison

Pt95Co5-ANN and Pt95Co5-H04 are two conditions of the same precious metal grade, Pt95Co5: ANN (annealed) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. Pt95Co5-H04 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 190 MPa (27.6 ksi) for Pt95Co5-ANN, about 3.3 times as much; tensile strength follows at 720 MPa (104 ksi) vs 430 MPa (62.4 ksi). In exchange, Pt95Co5-ANN is the more ductile: elongation 32% versus 3% for Pt95Co5-H04, and Pt95Co5-H04 is harder (209 HB vs 124 HB). Pt95Co5-ANN runs hotter in service (800°C vs 300°C continuous). On the shop floor, Pt95Co5-H04 machines more easily (fair vs poor) and Pt95Co5-ANN welds better (excellent vs very good).

Pt95Co5-ANNChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Pt95Co5-H04Choose it when strength drives the design, or when the part is machined in volume.

Pt95Co5-ANN vs Pt95Co5-H04: properties

Pt95Co5-ANNPt95Co5-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

190 MPa27.6 ksi
620 MPa89.9 ksi

Elongation at Break

32%
3%

Reduction in Area

45%
8%

Shear Strength

270 MPa39.2 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
280 MPa40.6 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

124 HB
209 HB

Hardness, Rockwell B

71 HRB
96 HRB

Hardness, Vickers

130 HV
220 HV

Same in both: Elastic (Young's) Modulus 172 GPa24.9 Msi · Shear Modulus 62 GPa9 Msi · Bulk Modulus 240 GPa34.8 Msi · Poisson's Ratio 0.39

Physical

Density and transition temperatures.

Same in both: Density 20 g/cm³0.72 lb/in³ · Melting Point (Solidus) 1,745°C3,173 °F · Liquidus Temperature 1,765°C3,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

35 W/m·K20.2 BTU/hr·ft·°F
33 W/m·K19.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

800°C1,472 °F
300°C572 °F

Same in both: Specific Heat Capacity 135 J/kg·K0.03 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 9.2 µm/m·K5.1 µin/in·°F · Latent Heat of Fusion 110 J/g47.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7 % IACS
6.7 % IACS

Electrical Resistivity

2.5×10⁻⁷ Ω·m9.84 µΩ·in
2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.25 V · Corrosion Resistance 96 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

17%
28%

Weldability

90 / 100
70 / 100

Formability (cold)

80 / 100
25 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 250,000 MJ/kg1.07×10⁸ BTU/lb · Embodied Carbon (primary production) 13,000 kg CO₂/kg · Embodied Water 250,000 L/kg29,957 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scalePt95Co5

Pt95Co5-ANN vs Pt95Co5-H04 — frequently asked

Is Pt95Co5-H04 stronger than Pt95Co5-ANN?

Yes. Pt95Co5-H04 has a typical yield strength of 620 MPa (89.9 ksi) against 190 MPa (27.6 ksi) for Pt95Co5-ANN — about 3.3 times as much. Tensile strength is 720 MPa (104 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, ANN or H04?

AC is the default Pt95Co5 condition in the FabDigit quote flow (neither ANN nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Pt95Co5-ANN or Pt95Co5-H04?

Pt95Co5-H04. Its machinability rates fair (50/100) against poor (30/100) for Pt95Co5-ANN; for welding the order is Pt95Co5-ANN first (excellent, 90/100) then Pt95Co5-H04 (very good, 70/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Pt95Co5-ANN and Pt95Co5-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.