FabDigitFabDigit

Precious Metal B780 1/2H vs B780-FH

Precious Metal · B780 temper comparison

B780 1/2H and B780-FH are two conditions of the same precious metal grade, B780: 1/2H (half hard) versus FH (full hard). The chemistry is identical, so every difference below comes from the condition. B780-FH is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 400 MPa (58 ksi) for B780 1/2H, about 25% more; tensile strength follows at 550 MPa (79.8 ksi) vs 470 MPa (68.2 ksi). In exchange, B780 1/2H is the more ductile: elongation 6% versus 3% for B780-FH, and B780-FH is harder (160 HV vs 135 HV).

B780 1/2HChoose it when the part is bent, formed or impact-loaded.

B780-FHChoose it when strength drives the design.

B780 1/2H vs B780-FH: properties

B780 1/2HB780-FH

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
500 MPa72.5 ksi

Elongation at Break

6%
3%

Shear Strength

295 MPa42.8 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
195 MPa28.3 ksi

Hardness, Rockwell B

74 HRB
84 HRB

Hardness, Vickers

135 HV
160 HV

Same in both: Elastic (Young's) Modulus 88 GPa12.8 Msi · Shear Modulus 33 GPa4.8 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.37 · Reduction in Area 60% · Hardness, Brinell 68 HB

Physical

Density and transition temperatures.

Same in both: Density 10.05 g/cm³0.36 lb/in³ · Melting Point (Solidus) 779°C1,434 °F · Liquidus Temperature 795°C1,463 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

308 W/m·K178 BTU/hr·ft·°F
305 W/m·K176 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
170°C338 °F

Same in both: Specific Heat Capacity 245 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 105 J/g45.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

75 % IACS
74 % IACS

Electrical Resistivity

2.3×10⁻⁸ Ω·m0.906 µΩ·in
2.33×10⁻⁸ Ω·m0.917 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0 V · Corrosion Resistance 75 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
62 / 100

Formability (cold)

50 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Weldability 60 / 100 · Castability 70 / 100 · Brazeability / Solderability 90 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,200 MJ/kg515,908 BTU/lb · Embodied Carbon (primary production) 95 kg CO₂/kg · Embodied Water 2,500 L/kg300 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleB780

B780 1/2H vs B780-FH — frequently asked

Is B780-FH stronger than B780 1/2H?

Yes. B780-FH has a typical yield strength of 500 MPa (72.5 ksi) against 400 MPa (58 ksi) for B780 1/2H — about 25% more. Tensile strength is 550 MPa (79.8 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, 1/2H or FH?

ANN is the default B780 condition in the FabDigit quote flow (neither 1/2H nor FH). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose B780 1/2H over B780-FH?

Pick B780 1/2H when the part is bent, formed or impact-loaded. Pick B780-FH when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in B780 1/2H and B780-FH side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.