FabDigitFabDigit

Precious Metal B596-H02 vs B596-OA

Precious Metal · B596 temper comparison

B596-H02 and B596-OA are two conditions of the same precious metal grade, B596: H02 (half hard) versus OA (order-hardened). The chemistry is identical, so every difference below comes from the condition. B596-OA is the stronger of the two: yield strength 780 MPa (113 ksi) against 450 MPa (65.3 ksi) for B596-H02, about 73% more; tensile strength follows at 900 MPa (131 ksi) vs 600 MPa (87 ksi). In exchange, B596-H02 is the more ductile: elongation 10% versus 3% for B596-OA, and B596-OA is harder (265 HV vs 175 HV). B596-OA runs hotter in service (250°C vs 200°C continuous) and B596-OA conducts heat better (100 W/m·K vs 60 W/m·K).

B596-H02Choose it when the part is bent, formed or impact-loaded.

B596-OAChoose it when strength drives the design, or when the part sees heat.

B596-H02 vs B596-OA: properties

B596-H02B596-OA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
900 MPa131 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
780 MPa113 ksi

Elongation at Break

10%
3%

Shear Strength

370 MPa53.7 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
330 MPa47.9 ksi

Hardness, Vickers

175 HV
265 HV

Same in both: Elastic (Young's) Modulus 92 GPa13.3 Msi · Shear Modulus 33 GPa4.8 Msi · Bulk Modulus 150 GPa21.8 Msi · Poisson's Ratio 0.4

Physical

Density and transition temperatures.

Same in both: Density 15.5 g/cm³0.56 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 895°C1,643 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

60 W/m·K34.7 BTU/hr·ft·°F
100 W/m·K57.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 155 J/kg·K0.04 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 95 J/g40.8 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

15 % IACS
25 % IACS

Electrical Resistivity

1.15×10⁻⁷ Ω·m4.53 µΩ·in
6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) 0.2 V · Corrosion Resistance 90 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
40%

Formability (cold)

55 / 100
20 / 100

Same in both: Weldability 75 / 100 · Castability 75 / 100 · Brazeability / Solderability 95 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200,000 MJ/kg8.6×10⁷ BTU/lb · Embodied Carbon (primary production) 12,000 kg CO₂/kg · Embodied Water 150,000 L/kg17,974 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleB596

B596-H02 vs B596-OA — frequently asked

Is B596-OA stronger than B596-H02?

Yes. B596-OA has a typical yield strength of 780 MPa (113 ksi) against 450 MPa (65.3 ksi) for B596-H02 — about 73% more. Tensile strength is 900 MPa (131 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, H02 or OA?

H is the default B596 condition in the FabDigit quote flow (neither H02 nor OA). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, B596-H02 or B596-OA?

B596-OA. Its machinability rates good (55/100) against fair (50/100) for B596-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in B596-H02 and B596-OA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.