FabDigitFabDigit

Precious Metal 950 Silver (Minerve) AS-CAST vs 950 Silver (Minerve)-H08

Precious Metal · 950 Silver (Minerve) temper comparison

950 Silver (Minerve) AS-CAST and 950 Silver (Minerve)-H08 are two conditions of the same precious metal grade, 950 Silver (Minerve): AS-CAST versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. 950 Silver (Minerve)-H08 is the stronger of the two: yield strength 400 MPa (58 ksi) against 70 MPa (10.2 ksi) for 950 Silver (Minerve) AS-CAST, about 5.7 times as much; tensile strength follows at 460 MPa (66.7 ksi) vs 210 MPa (30.5 ksi). In exchange, 950 Silver (Minerve) AS-CAST is the more ductile: elongation 25% versus 3% for 950 Silver (Minerve)-H08, and 950 Silver (Minerve)-H08 is harder (113 HB vs 48 HB). 950 Silver (Minerve) AS-CAST runs hotter in service (200°C vs 120°C continuous). On the shop floor, 950 Silver (Minerve)-H08 machines more easily (very good vs good) and 950 Silver (Minerve) AS-CAST welds better (very good vs good).

950 Silver (Minerve) AS-CASTChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

950 Silver (Minerve)-H08Choose it when strength drives the design, or when the part is machined in volume.

950 Silver (Minerve) AS-CAST vs 950 Silver (Minerve)-H08: properties

950 Silver (Minerve) AS-CAST950 Silver (Minerve)-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
76 GPa11 Msi

Tensile Strength (Ultimate)

210 MPa30.5 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
400 MPa58 ksi

Elongation at Break

25%
3%

Shear Strength

140 MPa20.3 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
140 MPa20.3 ksi

Hardness, Brinell

48 HB
113 HB

Hardness, Vickers

52 HV
120 HV

Same in both: Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 101 GPa14.6 Msi · Poisson's Ratio 0.37

Physical

Density and transition temperatures.

Same in both: Density 10.42 g/cm³0.38 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 915°C1,679 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

372 W/m·K215 BTU/hr·ft·°F
364 W/m·K210 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Specific Heat Capacity 236 J/kg·K0.06 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 106 J/g45.6 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

90 % IACS
88 % IACS

Electrical Resistivity

1.92×10⁻⁸ Ω·m0.756 µΩ·in
1.96×10⁻⁸ Ω·m0.772 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V · Corrosion Resistance 80 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

52%
65%

Weldability

70 / 100
60 / 100

Formability (cold)

60 / 100
20 / 100

Same in both: Castability 78 / 100 · Brazeability / Solderability 95 / 100 · Polishability 97 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,500 MJ/kg644,885 BTU/lb · Embodied Carbon (primary production) 105 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scale950 Silver (Minerve)

950 Silver (Minerve) AS-CAST vs 950 Silver (Minerve)-H08 — frequently asked

Is 950 Silver (Minerve)-H08 stronger than 950 Silver (Minerve) AS-CAST?

Yes. 950 Silver (Minerve)-H08 has a typical yield strength of 400 MPa (58 ksi) against 70 MPa (10.2 ksi) for 950 Silver (Minerve) AS-CAST — about 5.7 times as much. Tensile strength is 460 MPa (66.7 ksi) vs 210 MPa (30.5 ksi).

Which condition does FabDigit quote by default, AS-CAST or H08?

O is the default 950 Silver (Minerve) condition in the FabDigit quote flow (neither AS-CAST nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 950 Silver (Minerve) AS-CAST or 950 Silver (Minerve)-H08?

950 Silver (Minerve)-H08. Its machinability rates very good (72/100) against good (62/100) for 950 Silver (Minerve) AS-CAST; for welding the order is 950 Silver (Minerve) AS-CAST first (very good, 70/100) then 950 Silver (Minerve)-H08 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 950 Silver (Minerve) AS-CAST and 950 Silver (Minerve)-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.