PSU-GF30 GF30 and PSU-GF30 GF30-PTFE are two grades of the same polymer grade, PSU-GF30: GF30 (30% glass-fiber reinforced injection molding grade) versus GF30-PTFE (GF30 + PTFE lubricated bearing grade). The chemistry is identical, so every difference below comes from the condition. PSU-GF30 GF30 is the stronger of the two: tensile strength 108 MPa (15.7 ksi) against 85 MPa (12.3 ksi) for PSU-GF30 GF30-PTFE, about 27% more. PSU-GF30 GF30 is the more ductile: elongation 2.5% versus 2% for PSU-GF30 GF30-PTFE. PSU-GF30 GF30 is lighter (1.49 g/cm³ vs 1.58 g/cm³ for PSU-GF30 GF30-PTFE) and PSU-GF30 GF30 is stiffer (8.8 GPa vs 7.8 GPa). On the shop floor, PSU-GF30 GF30 welds better (fair vs not recommended).

PSU-GF30 GF30Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

PSU-GF30 GF30 vs PSU-GF30 GF30-PTFE: properties

PSU-GF30 GF30PSU-GF30 GF30-PTFE

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

8.8 GPa1.3 Msi
7.8 GPa1.1 Msi

Tensile Strength (Ultimate)

108 MPa15.7 ksi
85 MPa12.3 ksi

Elongation at Break

2.5%
2%

Compressive Strength

130 MPa18.9 ksi
115 MPa16.7 ksi

Flexural Strength

160 MPa23.2 ksi
130 MPa18.9 ksi

Flexural Modulus

8.3 GPa1.2 Msi
7.5 GPa1.1 Msi

Shear Strength

65 MPa9.4 ksi
55 MPa8 ksi

Fracture Toughness (K_IC)

3 MPa·√m2.7 ksi·√in
2.5 MPa·√m2.3 ksi·√in

Izod Impact, Notched

85 J/m1.6 ft·lbf/in
55 J/m1 ft·lbf/in

Hardness, Rockwell M

92 HRM
88 HRM

Hardness, Rockwell R

122 HRR
118 HRR

Same in both: Shear Modulus 3.2 GPa0.46 Msi · Poisson's Ratio 0.38 · Compressive Modulus 7.5 GPa1.1 Msi

Physical

Density and transition temperatures.

Density

1.49 g/cm³0.05 lb/in³
1.58 g/cm³0.06 lb/in³

Same in both: Glass Transition (Tg) 185°C365 °F · Water Absorption (24 h) 0.22% · Water Absorption (Saturation) 0.6%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.3 W/m·K0.17 BTU/hr·ft·°F
0.32 W/m·K0.18 BTU/hr·ft·°F

Max Service Temperature (continuous)

165°C329 °F
160°C320 °F

Heat Deflection Temp. @ 0.45 MPa

185°C365 °F
182°C360 °F

Heat Deflection Temp. @ 1.8 MPa

180°C356 °F
176°C349 °F

Vicat Softening Point (B50)

188°C370 °F
186°C367 °F

Limiting Oxygen Index

32%
34%

Same in both: Specific Heat Capacity 1,100 J/kg·K0.26 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Min Service Temperature -100°C-148 °F · Max Service Temperature (short-term) 190°C374 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 19 kV/mm483 V/mil · Dielectric Constant (1 MHz) 3.7 · Dissipation Factor (1 MHz) 0.006 · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 150 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
87 / 100

Same in both: UV / Weathering Resistance 30 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Weldability

40 / 100
10 / 100

Formability (cold)

15 / 100
10 / 100

Mold Shrinkage

0.3%
0.35%

Same in both: Polishability 30 / 100 · Melt Flow Rate 6 g/10 min · Processing Melt Temperature (typ.) 355°C671 °F · Mold Temperature (typ.) 145°C293 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

PSU-GF30 GF30 vs PSU-GF30 GF30-PTFE — frequently asked

Is PSU-GF30 GF30 stronger than PSU-GF30 GF30-PTFE?

Yes. PSU-GF30 GF30 has a typical tensile strength of 108 MPa (15.7 ksi) against 85 MPa (12.3 ksi) for PSU-GF30 GF30-PTFE — about 27% more.

Which grade does FabDigit quote by default, GF30 or GF30-PTFE?

GF30 is the default PSU-GF30 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, PSU-GF30 GF30 or PSU-GF30 GF30-PTFE?

PSU-GF30 GF30-PTFE. Its machinability rates good (55/100) against fair (50/100) for PSU-GF30 GF30; for welding the order is PSU-GF30 GF30 first (fair, 40/100) then PSU-GF30 GF30-PTFE (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in PSU-GF30 GF30 and PSU-GF30 GF30-PTFE side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.