FabDigitFabDigit

PPE-GF30 GF30 vs PPE-GF30 GF40

Polymer · PPE-GF30 grade comparison

PPE-GF30 GF30 and PPE-GF30 GF40 are two grades of the same polymer grade, PPE-GF30: GF30 (standard 30% glass-fiber reinforced modified PPE) versus GF40 (40% glass-fiber reinforced modified PPE). The chemistry is identical, so every difference below comes from the condition. PPE-GF30 GF40 is the stronger of the two: tensile strength 135 MPa (19.6 ksi) against 120 MPa (17.4 ksi) for PPE-GF30 GF30, about 13% more. In exchange, PPE-GF30 GF30 is the more ductile: elongation 2.5% versus 2% for PPE-GF30 GF40. PPE-GF30 GF30 is lighter (1.28 g/cm³ vs 1.42 g/cm³ for PPE-GF30 GF40) and PPE-GF30 GF40 is stiffer (11.5 GPa vs 9 GPa).

PPE-GF30 GF30Choose it when the part is bent, formed or impact-loaded, or when weight is the constraint.

PPE-GF30 GF40Choose it when strength drives the design.

PPE-GF30 GF30 vs PPE-GF30 GF40: properties

PPE-GF30 GF30PPE-GF30 GF40

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

9 GPa1.3 Msi
11.5 GPa1.7 Msi

Tensile Strength (Ultimate)

120 MPa17.4 ksi
135 MPa19.6 ksi

Elongation at Break

2.5%
2%

Flexural Strength

160 MPa23.2 ksi
185 MPa26.8 ksi

Flexural Modulus

8.3 GPa1.2 Msi
11 GPa1.6 Msi

Izod Impact, Notched

90 J/m1.7 ft·lbf/in
105 J/m2 ft·lbf/in

Same in both: Shear Modulus 3.3 GPa0.48 Msi · Poisson's Ratio 0.36 · Compressive Strength 120 MPa17.4 ksi · Compressive Modulus 8 GPa1.2 Msi · Shear Strength 68 MPa9.9 ksi · Fracture Toughness (K_IC) 3.5 MPa·√m3.2 ksi·√in · Hardness, Shore D 88 Shore D · Hardness, Rockwell M 88 HRM · Hardness, Rockwell R 118 HRR

Physical

Density and transition temperatures.

Density

1.28 g/cm³0.05 lb/in³
1.42 g/cm³0.05 lb/in³

Same in both: Glass Transition (Tg) 148°C298 °F · Water Absorption (24 h) 0.07% · Water Absorption (Saturation) 0.4%

Thermal

How each material carries heat and how hot it can run.

Thermal Expansion (CTE, 20–100 °C)

25 µm/m·K13.9 µin/in·°F
18 µm/m·K10 µin/in·°F

Heat Deflection Temp. @ 1.8 MPa

145°C293 °F
152°C306 °F

Same in both: Thermal Conductivity 0.22 W/m·K0.13 BTU/hr·ft·°F · Specific Heat Capacity 1,300 J/kg·K0.31 BTU/lb·°F · Max Service Temperature (continuous) 110°C230 °F · Min Service Temperature -40°C-40 °F · Heat Deflection Temp. @ 0.45 MPa 158°C316 °F · Vicat Softening Point (B50) 160°C320 °F · Limiting Oxygen Index 25% · Max Service Temperature (short-term) 145°C293 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 1×10¹⁴ Ω·m3.94×10²¹ µΩ·in · Dielectric Strength 28 kV/mm711 V/mil · Dielectric Constant (1 MHz) 3.2 · Dissipation Factor (1 MHz) 0.004 · Volume Resistivity 1×10¹⁶ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 250 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 85 / 100 · UV / Weathering Resistance 35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
48 / 100

Mold Shrinkage

0.2%
0.15%

Same in both: Weldability 45 / 100 · Formability (cold) 10 / 100 · Polishability 30 / 100 · Melt Flow Rate 8 g/10 min · Processing Melt Temperature (typ.) 290°C554 °F · Mold Temperature (typ.) 95°C203 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

PPE-GF30 GF30 vs PPE-GF30 GF40 — frequently asked

Is PPE-GF30 GF40 stronger than PPE-GF30 GF30?

Yes. PPE-GF30 GF40 has a typical tensile strength of 135 MPa (19.6 ksi) against 120 MPa (17.4 ksi) for PPE-GF30 GF30 — about 13% more.

Which grade does FabDigit quote by default, GF30 or GF40?

GF30 is the default PPE-GF30 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, PPE-GF30 GF30 or PPE-GF30 GF40?

PPE-GF30 GF30. Its machinability rates good (55/100) against fair (48/100) for PPE-GF30 GF40.

Ready to make it?

Upload a CAD file and FabDigit prices the part in PPE-GF30 GF30 and PPE-GF30 GF40 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.