FabDigitFabDigit

LCP Type I GF15 vs LCP Type I GF30

Polymer · LCP Type I grade comparison

LCP Type I GF15 and LCP Type I GF30 are two grades of the same polymer grade, LCP Type I: GF15 (15 % glass fibre reinforced) versus GF30 (30 % glass fibre reinforced). The chemistry is identical, so every difference below comes from the condition. LCP Type I GF15 is the more ductile: elongation 2.2% versus 1.8% for LCP Type I GF30. LCP Type I GF15 is lighter (1.5 g/cm³ vs 1.62 g/cm³ for LCP Type I GF30) and LCP Type I GF30 is stiffer (16 GPa vs 13.5 GPa).

LCP Type I GF15Choose it when the part is bent, formed or impact-loaded, or when weight is the constraint.

LCP Type I GF30Choose it when the part sees heat.

LCP Type I GF15 vs LCP Type I GF30: properties

LCP Type I GF15LCP Type I GF30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

13.5 GPa2 Msi
16 GPa2.3 Msi

Tensile Strength (Ultimate)

145 MPa21 ksi
150 MPa21.8 ksi

Elongation at Break

2.2%
1.8%

Flexural Strength

175 MPa25.4 ksi
195 MPa28.3 ksi

Flexural Modulus

12.5 GPa1.8 Msi
15 GPa2.2 Msi

Izod Impact, Notched

130 J/m2.4 ft·lbf/in
110 J/m2.1 ft·lbf/in

Same in both: Shear Modulus 1.2 GPa0.17 Msi · Poisson's Ratio 0.38 · Compressive Strength 65 MPa9.4 ksi · Compressive Modulus 7 GPa1 Msi · Shear Strength 55 MPa8 ksi · Hardness, Shore D 88 Shore D · Hardness, Rockwell M 75 HRM

Physical

Density and transition temperatures.

Density

1.5 g/cm³0.05 lb/in³
1.62 g/cm³0.06 lb/in³

Same in both: Melting Temperature (Tm) 355°C671 °F · Glass Transition (Tg) 145°C293 °F · Water Absorption (24 h) 0.02% · Water Absorption (Saturation) 0.1%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.3 W/m·K0.17 BTU/hr·ft·°F
0.4 W/m·K0.23 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

10 µm/m·K5.6 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Max Service Temperature (continuous)

220°C428 °F
240°C464 °F

Heat Deflection Temp. @ 0.45 MPa

275°C527 °F
340°C644 °F

Heat Deflection Temp. @ 1.8 MPa

285°C545 °F
320°C608 °F

Same in both: Specific Heat Capacity 1,150 J/kg·K0.27 BTU/lb·°F · Min Service Temperature -100°C-148 °F · Limiting Oxygen Index 40% · Max Service Temperature (short-term) 300°C572 °F

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.3
4

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Dissipation Factor (1 MHz) 0.004 · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 92 / 100 · UV / Weathering Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
42 / 100

Mold Shrinkage

0.15%
0.2%

Same in both: Weldability 20 / 100 · Formability (cold) 20 / 100 · Polishability 45 / 100 · Processing Melt Temperature (typ.) 385°C725 °F · Mold Temperature (typ.) 120°C248 °F

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 250 MJ/kg107,481 BTU/lb · Embodied Carbon (primary production) 9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

LCP Type I GF15 vs LCP Type I GF30 — frequently asked

What is the difference between LCP Type I GF15 and LCP Type I GF30?

LCP Type I GF15 and LCP Type I GF30 are two grades of the same polymer grade, LCP Type I: GF15 (15 % glass fibre reinforced) versus GF30 (30 % glass fibre reinforced). The chemistry is identical, so every difference below comes from the condition. LCP Type I GF15 is the more ductile: elongation 2.2% versus 1.8% for LCP Type I GF30.

Which grade does FabDigit quote by default, GF15 or GF30?

UF is the default LCP Type I condition in the FabDigit quote flow (neither GF15 nor GF30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, LCP Type I GF15 or LCP Type I GF30?

LCP Type I GF15, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for LCP Type I GF30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP Type I GF15 and LCP Type I GF30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.