FabDigitFabDigit

Flexible Resin vs Accura SL 5530

Polymer · grade comparison

Flexible Resin and SL 5530 are both polymer grades.

Flexible Resin vs SL 5530: properties

Flexible ResinSL 5530

Properties

Yield strength

4 MPa0.58 ksi
50 MPa7.3 ksi

Tensile strength

9 MPa1.3 ksi
50 MPa7.3 ksi

Elongation at break

120%
—

Elastic modulus (Young's)

0.01 GPa0 Msi
—

Density

1.12 g/cm³0.04 lb/in³
1.18 g/cm³0.04 lb/in³

Max service temp

65°C149 °F
240°C464 °F

Thermal conductivity

0.2 W/m·K
—

Machinability

15 / 100
40 / 100

Weldability

40 / 100
5 / 100

Formability

92 / 100
5 / 100

Same in both: Electrical conductivity 0 % IACS

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scaleFlexible ResinAccura SL 5530

Manufacturing and finishing

CapabilityFlexible ResinSL 5530
Default conditionShore A 80—
Relative cost$$$ Premium$$$ Premium
Min. machined wall——
Best machined surface——

Both are offered for Injection molding and 3D printing. Both take the same 12 finishes: Chrome Plating (Plastic), Conductive Coating, Dyeing (Nylon), EMI Shielding Coating, Painting, Primer Coating, Soft Touch Coating, Spray Painting, Tinted Coating, UV Coating, Vacuum Metallization, Waterproof Coating.

Flexible Resin vs SL 5530 — frequently asked

What is the difference between Flexible Resin and SL 5530?

Flexible Resin and SL 5530 are both polymer grades.

Which is cheaper, Flexible Resin or SL 5530?

Both sit in the same relative cost tier ($$$, premium); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Flexible Resin and SL 5530 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.