X-750-EQ and X-750-STA are two conditions of the same nickel alloy grade, X-750: EQ (equalized) versus STA (solution treated and aged). The chemistry is identical, so every difference below comes from the condition. X-750-STA is the stronger of the two: yield strength 815 MPa (118 ksi) against 550 MPa (79.8 ksi) for X-750-EQ, about 48% more; tensile strength follows at 1,200 MPa (174 ksi) vs 900 MPa (131 ksi). In exchange, X-750-EQ is the more ductile: elongation 30% versus 24% for X-750-STA, and X-750-STA is harder (302 HB vs 235 HB). X-750-STA runs hotter in service (760°C vs 650°C continuous). On the shop floor, X-750-EQ welds better (50 vs 40 out of 100).

X-750-EQChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

X-750-STAChoose it when strength drives the design, or when the part sees heat.

X-750-EQ vs X-750-STA: properties

X-750-EQX-750-STA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

900 MPa131 ksi
1,200 MPa174 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
815 MPa118 ksi

Elongation at Break

30%
24%

Reduction in Area

45%
35%

Compressive Strength

570 MPa82.7 ksi
840 MPa122 ksi

Shear Strength

590 MPa85.6 ksi
730 MPa106 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
450 MPa65.3 ksi

Fracture Toughness (K_IC)

130 MPa·√m118 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

80 J59 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

235 HB
302 HB

Hardness, Rockwell C

22 HRC
32 HRC

Hardness, Vickers

248 HV
320 HV

Same in both: Elastic (Young's) Modulus 214 GPa31 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 188 GPa27.3 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.28 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,393°C2,539 °F · Liquidus Temperature 1,427°C2,601 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

650°C1,202 °F
760°C1,400 °F

Same in both: Thermal Conductivity 12 W/m·K6.9 BTU/hr·ft·°F · Specific Heat Capacity 431 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.6 µm/m·K7 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.4 % IACS · Electrical Resistivity 1.22×10⁻⁶ Ω·m48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
12%

Weldability

50 / 100
40 / 100

Formability (cold)

35 / 100
15 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 290 MJ/kg124,678 BTU/lb · Embodied Carbon (primary production) 17.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleX-750

X-750-EQ vs X-750-STA — frequently asked

Is X-750-STA stronger than X-750-EQ?

Yes. X-750-STA has a typical yield strength of 815 MPa (118 ksi) against 550 MPa (79.8 ksi) for X-750-EQ — about 48% more. Tensile strength is 1,200 MPa (174 ksi) vs 900 MPa (131 ksi).

Which condition does FabDigit quote by default, EQ or STA?

STA is the default X-750 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, X-750-EQ or X-750-STA?

X-750-EQ. Its weldability rates fair (50/100) against fair (40/100) for X-750-STA.

Ready to make it?

Upload a CAD file and FabDigit prices the part in X-750-EQ and X-750-STA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.