Nickel Alloy N06219-AW vs N06219-CW
Nickel Alloy · N06219 temper comparison
N06219-AW and N06219-CW are two conditions of the same nickel alloy grade, N06219: AW (as-welded deposit) versus CW (cold worked). The chemistry is identical, so every difference below comes from the condition. N06219-CW is the stronger of the two: yield strength 760 MPa (110 ksi) against 450 MPa (65.3 ksi) for N06219-AW, about 69% more; tensile strength follows at 1,000 MPa (145 ksi) vs 740 MPa (107 ksi). In exchange, N06219-AW is the more ductile: elongation 40% versus 20% for N06219-CW, and N06219-CW is harder (275 HB vs 205 HB). N06219-AW runs hotter in service (900°C vs 425°C continuous).
N06219-AWChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
N06219-CWChoose it when strength drives the design.
N06219-AW vs N06219-CW: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 180 GPa26.1 Msi · Poisson's Ratio 0.31
Physical
Density and transition temperatures.
Same in both: Density 8.7 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,325°C2,417 °F · Liquidus Temperature 1,370°C2,498 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.4 µm/m·K6.9 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 1.4 % IACS · Electrical Resistivity 1.28×10⁻⁶ Ω·m50.4 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 88 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 35 / 100 · Brazeability / Solderability 55 / 100 · Polishability 75 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 140 MJ/kg60,189 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%
Strength versus weight
Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
N06219-AW vs N06219-CW — frequently asked
Is N06219-CW stronger than N06219-AW?
Yes. N06219-CW has a typical yield strength of 760 MPa (110 ksi) against 450 MPa (65.3 ksi) for N06219-AW — about 69% more. Tensile strength is 1,000 MPa (145 ksi) vs 740 MPa (107 ksi).
Which condition does FabDigit quote by default, AW or CW?
SA is the default N06219 condition in the FabDigit quote flow (neither AW nor CW). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, N06219-AW or N06219-CW?
N06219-CW, by a small margin. Both rate poor for machinability — 22/100 against 16/100 for N06219-AW; for welding the order is N06219-AW first (very good, 80/100) then N06219-CW (very good, 72/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in N06219-AW and N06219-CW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.