FabDigitFabDigit

Nickel Alloy Invar 36-CD vs Invar 36-HR

Nickel Alloy · Invar 36 temper comparison

Invar 36-CD and Invar 36-HR are two conditions of the same nickel alloy grade, Invar 36: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. Invar 36-CD is the stronger of the two: yield strength 560 MPa (81.2 ksi) against 300 MPa (43.5 ksi) for Invar 36-HR, about 87% more; tensile strength follows at 700 MPa (102 ksi) vs 500 MPa (72.5 ksi). In exchange, Invar 36-HR is the more ductile: elongation 35% versus 15% for Invar 36-CD, and Invar 36-CD is harder (210 HB vs 150 HB).

Invar 36-CDChoose it when strength drives the design.

Invar 36-HRChoose it when the part is bent, formed or impact-loaded.

Invar 36-CD vs Invar 36-HR: properties

Invar 36-CDInvar 36-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

141 GPa20.5 Msi
143 GPa20.7 Msi

Tensile Strength (Ultimate)

700 MPa102 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

560 MPa81.2 ksi
300 MPa43.5 ksi

Elongation at Break

15%
35%

Reduction in Area

70%
65%

Shear Strength

330 MPa47.9 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
250 MPa36.3 ksi

Charpy V-Notch Impact (RT)

180 J133 ft·lbf
165 J122 ft·lbf

Hardness, Brinell

210 HB
150 HB

Hardness, Rockwell B

96 HRB
80 HRB

Hardness, Vickers

225 HV
158 HV

Same in both: Shear Modulus 55 GPa8 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.1 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,427°C2,601 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Expansion (CTE, 20–100 °C)

1.8 µm/m·K1 µin/in·°F
1.6 µm/m·K0.89 µin/in·°F

Same in both: Thermal Conductivity 10.5 W/m·K6.1 BTU/hr·ft·°F · Specific Heat Capacity 515 J/kg·K0.12 BTU/lb·°F · Latent Heat of Fusion 275 J/g118 BTU/lb · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.1 % IACS · Electrical Resistivity 8.2×10⁻⁷ Ω·m32.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.35 V · Corrosion Resistance 32 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Formability (cold)

50 / 100
70 / 100

Same in both: Machinability 30 / 100 · Weldability 70 / 100 · Castability 40 / 100 · Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 90 MJ/kg38,693 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleInvar 36

Invar 36-CD vs Invar 36-HR — frequently asked

Is Invar 36-CD stronger than Invar 36-HR?

Yes. Invar 36-CD has a typical yield strength of 560 MPa (81.2 ksi) against 300 MPa (43.5 ksi) for Invar 36-HR — about 87% more. Tensile strength is 700 MPa (102 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, CD or HR?

O is the default Invar 36 condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Invar 36-CD over Invar 36-HR?

Pick Invar 36-CD when strength drives the design. Pick Invar 36-HR when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Invar 36-CD and Invar 36-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.