FabDigitFabDigit

Nickel Alloy 2.4889 Annealed vs 2.4889 HRAnn

Nickel Alloy · 2.4889 temper comparison

2.4889 Annealed and 2.4889 HRAnn are two conditions of the same nickel alloy grade, 2.4889: Annealed versus HRAnn (hot rolled + annealed bar / rod). The chemistry is identical, so every difference below comes from the condition. 2.4889 Annealed is the stronger of the two: yield strength 400 MPa (58 ksi) against 350 MPa (50.8 ksi) for 2.4889 HRAnn, about 14% more; tensile strength follows at 760 MPa (110 ksi) vs 720 MPa (104 ksi). In exchange, 2.4889 HRAnn is the more ductile: elongation 35% versus 30% for 2.4889 Annealed, and 2.4889 Annealed is harder (170 HB vs 160 HB).

2.4889 AnnealedChoose it when strength drives the design.

2.4889 HRAnnChoose it when the part is bent, formed or impact-loaded.

2.4889 Annealed vs 2.4889 HRAnn: properties

2.4889 Annealed2.4889 HRAnn

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
350 MPa50.8 ksi

Elongation at Break

30%
35%

Reduction in Area

60%
65%

Shear Strength

500 MPa72.5 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
280 MPa40.6 ksi

Hardness, Brinell

170 HB
160 HB

Hardness, Rockwell B

87 HRB
83 HRB

Hardness, Vickers

180 HV
168 HV

Same in both: Elastic (Young's) Modulus 216 GPa31.3 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 180 GPa26.1 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.12 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,380°C2,516 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 14 W/m·K8.1 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.5 µm/m·K7.5 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Max Service Temperature (continuous) 1,250°C2,282 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.5 % IACS · Electrical Resistivity 1.18×10⁻⁶ Ω·m46.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
20%

Same in both: Weldability 65 / 100 · Formability (cold) 80 / 100 · Castability 40 / 100 · Brazeability / Solderability 55 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 160 MJ/kg68,788 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scale2.4889

2.4889 Annealed vs 2.4889 HRAnn — frequently asked

Is 2.4889 Annealed stronger than 2.4889 HRAnn?

Yes. 2.4889 Annealed has a typical yield strength of 400 MPa (58 ksi) against 350 MPa (50.8 ksi) for 2.4889 HRAnn — about 14% more. Tensile strength is 760 MPa (110 ksi) vs 720 MPa (104 ksi).

Which condition does FabDigit quote by default, Annealed or HRAnn?

Annealed is the default 2.4889 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 2.4889 Annealed over 2.4889 HRAnn?

Pick 2.4889 Annealed when strength drives the design. Pick 2.4889 HRAnn when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2.4889 Annealed and 2.4889 HRAnn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.