FabDigitFabDigit

Magnesium Alloy ZM5-F vs ZM5-T6

Magnesium Alloy · ZM5 temper comparison

ZM5-F and ZM5-T6 are two conditions of the same magnesium alloy grade, ZM5: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZM5-T6 is the stronger of the two: yield strength 140 MPa (20.3 ksi) against 90 MPa (13.1 ksi) for ZM5-F, about 56% more; tensile strength follows at 255 MPa (37 ksi) vs 165 MPa (23.9 ksi). ZM5-T6 is the more ductile: elongation 4% versus 2.5% for ZM5-F, and ZM5-T6 is harder (70 HB vs 55 HB). ZM5-T6 conducts electricity better (13.5 % IACS vs 12 % IACS).

ZM5-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZM5-F vs ZM5-T6: properties

ZM5-FZM5-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
140 MPa20.3 ksi

Elongation at Break

2.5%
4%

Reduction in Area

3%
5%

Compressive Strength

290 MPa42.1 ksi
330 MPa47.9 ksi

Shear Strength

125 MPa18.1 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

11 MPa·√m10 ksi·√in
12 MPa·√m10.9 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.5 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

55 HB
70 HB

Hardness, Vickers

60 HV
75 HV

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 1.81 g/cm³0.07 lb/in³ · Melting Point (Solidus) 470°C878 °F · Liquidus Temperature 595°C1,103 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

65 W/m·K37.6 BTU/hr·ft·°F
72 W/m·K41.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
130°C266 °F

Same in both: Specific Heat Capacity 1,020 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26 µm/m·K14.4 µin/in·°F · Latent Heat of Fusion 373 J/g160 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

12 % IACS
13.5 % IACS

Electrical Resistivity

1.4×10⁻⁷ Ω·m5.51 µΩ·in
1.28×10⁻⁷ Ω·m5.04 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

22 / 100
20 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

60 / 100
55 / 100

Formability (cold)

15 / 100
12 / 100

Same in both: Machinability 95 / 100 · Machinability Rating (AISI 1212 = 100 %) 400% · Castability 90 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 330 MJ/kg141,875 BTU/lb · Embodied Carbon (primary production) 30 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleZM5

ZM5-F vs ZM5-T6 — frequently asked

Is ZM5-T6 stronger than ZM5-F?

Yes. ZM5-T6 has a typical yield strength of 140 MPa (20.3 ksi) against 90 MPa (13.1 ksi) for ZM5-F — about 56% more. Tensile strength is 255 MPa (37 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, F or T6?

T4 is the default ZM5 condition in the FabDigit quote flow (neither F nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, ZM5-F or ZM5-T6?

ZM5-F. Its weldability rates good (60/100) against good (55/100) for ZM5-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZM5-F and ZM5-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.