ZK61A-T5 and ZK61A-T6 are two conditions of the same magnesium alloy grade, ZK61A: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZK61A-T6 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 185 MPa (26.8 ksi) for ZK61A-T5, about 5% more. ZK61A-T6 is the more ductile: elongation 10% versus 8% for ZK61A-T5, and ZK61A-T6 is harder (70 HB vs 65 HB).

ZK61A-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZK61A-T5 vs ZK61A-T6: properties

ZK61A-T5ZK61A-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

185 MPa26.8 ksi
195 MPa28.3 ksi

Elongation at Break

8%
10%

Compressive Strength

185 MPa26.8 ksi
190 MPa27.6 ksi

Shear Strength

160 MPa23.2 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

83 MPa12 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

4 J2.6 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

65 HB
70 HB

Hardness, Vickers

68 HV
72 HV

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.35 · Tensile Strength (Ultimate) 310 MPa45 ksi · Fracture Toughness (K_IC) 14 MPa·√m12.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 1.83 g/cm³0.07 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 122 W/m·K70.5 BTU/hr·ft·°F · Specific Heat Capacity 1,000 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 27 µm/m·K15 µin/in·°F · Latent Heat of Fusion 340 J/g146 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 25 % IACS · Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -1.6 V · Corrosion Resistance 22 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 97 / 100 · Machinability Rating (AISI 1212 = 100 %) 400% · Weldability 30 / 100 · Formability (cold) 15 / 100 · Castability 55 / 100 · Brazeability / Solderability 15 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 300 MJ/kg128,977 BTU/lb · Embodied Carbon (primary production) 26 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleZK61A

ZK61A-T5 vs ZK61A-T6 — frequently asked

Is ZK61A-T6 stronger than ZK61A-T5?

Yes. ZK61A-T6 has a typical yield strength of 195 MPa (28.3 ksi) against 185 MPa (26.8 ksi) for ZK61A-T5 — about 5% more. Tensile strength is 310 MPa (45 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, T5 or T6?

T6 is the default ZK61A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZK61A-T5 over ZK61A-T6?

Pick ZK61A-T6 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZK61A-T5 and ZK61A-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.