ZK60A-F and ZK60A-T5 are two conditions of the same magnesium alloy grade, ZK60A: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZK60A-T5 is the stronger of the two: yield strength 305 MPa (44.2 ksi) against 260 MPa (37.7 ksi) for ZK60A-F, about 17% more; tensile strength follows at 365 MPa (52.9 ksi) vs 340 MPa (49.3 ksi). In exchange, ZK60A-F is the more ductile: elongation 14% versus 11% for ZK60A-T5, and ZK60A-T5 is harder (84 HB vs 75 HB).

ZK60A-FChoose it when the part is bent, formed or impact-loaded.

ZK60A-T5Choose it when strength drives the design.

ZK60A-F vs ZK60A-T5: properties

ZK60A-FZK60A-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

340 MPa49.3 ksi
365 MPa52.9 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
305 MPa44.2 ksi

Elongation at Break

14%
11%

Compressive Strength

215 MPa31.2 ksi
250 MPa36.3 ksi

Shear Strength

165 MPa23.9 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
140 MPa20.3 ksi

Fracture Toughness (K_IC)

14 MPa·√m12.7 ksi·√in
13 MPa·√m11.8 ksi·√in

Charpy V-Notch Impact (RT)

6 J4.4 ft·lbf
6 J4.1 ft·lbf

Hardness, Brinell

75 HB
84 HB

Hardness, Vickers

78 HV
88 HV

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 16.5 GPa2.4 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 1.83 g/cm³0.07 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 121 W/m·K69.9 BTU/hr·ft·°F · Specific Heat Capacity 1,000 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26 µm/m·K14.4 µin/in·°F · Latent Heat of Fusion 350 J/g150 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -80°C-112 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
29 % IACS

Electrical Resistivity

6.1×10⁻⁸ Ω·m2.4 µΩ·in
5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -1.55 V · Corrosion Resistance 25 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

30 / 100
22 / 100

Same in both: Machinability 95 / 100 · Machinability Rating (AISI 1212 = 100 %) 400% · Weldability 25 / 100 · Castability 40 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 300 MJ/kg128,977 BTU/lb · Embodied Carbon (primary production) 30 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleZK60A

ZK60A-F vs ZK60A-T5 — frequently asked

Is ZK60A-T5 stronger than ZK60A-F?

Yes. ZK60A-T5 has a typical yield strength of 305 MPa (44.2 ksi) against 260 MPa (37.7 ksi) for ZK60A-F — about 17% more. Tensile strength is 365 MPa (52.9 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default ZK60A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZK60A-F over ZK60A-T5?

Pick ZK60A-F when the part is bent, formed or impact-loaded. Pick ZK60A-T5 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZK60A-F and ZK60A-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.