ZE63A-F and ZE63A-T6 are two conditions of the same magnesium alloy grade, ZE63A: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZE63A-T6 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 145 MPa (21 ksi) for ZE63A-F, about 31% more; tensile strength follows at 300 MPa (43.5 ksi) vs 200 MPa (29 ksi). ZE63A-T6 is the more ductile: elongation 10% versus 3% for ZE63A-F, and ZE63A-T6 is harder (65 HB vs 55 HB).

ZE63A-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZE63A-F vs ZE63A-T6: properties

ZE63A-FZE63A-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
190 MPa27.6 ksi

Elongation at Break

3%
10%

Compressive Strength

150 MPa21.8 ksi
195 MPa28.3 ksi

Shear Strength

135 MPa19.6 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
110 MPa16 ksi

Fracture Toughness (K_IC)

12 MPa·√m10.9 ksi·√in
15 MPa·√m13.7 ksi·√in

Hardness, Brinell

55 HB
65 HB

Same in both: Elastic (Young's) Modulus 45 GPa6.5 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 1.87 g/cm³0.07 lb/in³ · Melting Point (Solidus) 510°C950 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 1,000 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 27 µm/m·K15 µin/in·°F · Latent Heat of Fusion 340 J/g146 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -70°C-94 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

24 % IACS
26 % IACS

Electrical Resistivity

7.2×10⁻⁸ Ω·m2.83 µΩ·in
6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

20 / 100
22 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

75 / 100
70 / 100

Same in both: Machinability 92 / 100 · Machinability Rating (AISI 1212 = 100 %) 400% · Castability 75 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 360 MJ/kg154,772 BTU/lb · Embodied Carbon (primary production) 38 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleZE63A

ZE63A-F vs ZE63A-T6 — frequently asked

Is ZE63A-T6 stronger than ZE63A-F?

Yes. ZE63A-T6 has a typical yield strength of 190 MPa (27.6 ksi) against 145 MPa (21 ksi) for ZE63A-F — about 31% more. Tensile strength is 300 MPa (43.5 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default ZE63A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, ZE63A-F or ZE63A-T6?

ZE63A-F. Its weldability rates very good (75/100) against very good (70/100) for ZE63A-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZE63A-F and ZE63A-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.