FabDigitFabDigit

Magnesium Alloy WE54A-F vs WE54A-T6

Magnesium Alloy · WE54A temper comparison

WE54A-F and WE54A-T6 are two conditions of the same magnesium alloy grade, WE54A: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. WE54A-T6 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 105 MPa (15.2 ksi) for WE54A-F, about 81% more; tensile strength follows at 275 MPa (39.9 ksi) vs 190 MPa (27.6 ksi). In exchange, WE54A-F is the more ductile: elongation 5% versus 4% for WE54A-T6, and WE54A-T6 is harder (85 HB vs 60 HB). WE54A-T6 runs hotter in service (250°C vs 150°C continuous) and WE54A-T6 conducts electricity better (10 % IACS vs 9 % IACS).

WE54A-FChoose it when the part is bent, formed or impact-loaded.

WE54A-T6Choose it when strength drives the design, or when the part sees heat.

WE54A-F vs WE54A-T6: properties

WE54A-FWE54A-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

190 MPa27.6 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
190 MPa27.6 ksi

Elongation at Break

5%
4%

Shear Strength

115 MPa16.7 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
100 MPa14.5 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
15 MPa·√m13.7 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

60 HB
85 HB

Hardness, Vickers

63 HV
90 HV

Same in both: Elastic (Young's) Modulus 44 GPa6.4 Msi · Shear Modulus 17 GPa2.5 Msi · Bulk Modulus 32 GPa4.6 Msi · Poisson's Ratio 0.27

Physical

Density and transition temperatures.

Same in both: Density 1.85 g/cm³0.07 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
52 W/m·K30 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26.7 µm/m·K14.8 µin/in·°F · Latent Heat of Fusion 350 J/g150 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

9 % IACS
10 % IACS

Electrical Resistivity

1.9×10⁻⁷ Ω·m7.48 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
32 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.55 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

90 / 100
88 / 100

Machinability Rating (AISI 1212 = 100 %)

310%
300%

Weldability

75 / 100
70 / 100

Formability (cold)

14 / 100
12 / 100

Same in both: Castability 72 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 350 MJ/kg150,473 BTU/lb · Embodied Carbon (primary production) 28 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 8%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleWE54A

WE54A-F vs WE54A-T6 — frequently asked

Is WE54A-T6 stronger than WE54A-F?

Yes. WE54A-T6 has a typical yield strength of 190 MPa (27.6 ksi) against 105 MPa (15.2 ksi) for WE54A-F — about 81% more. Tensile strength is 275 MPa (39.9 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default WE54A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, WE54A-F or WE54A-T6?

WE54A-F. Its weldability rates very good (75/100) against very good (70/100) for WE54A-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in WE54A-F and WE54A-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.