Magnesium Alloy QE22 HIP+T6 vs QE22-T4

Magnesium Alloy · QE22 temper comparison

QE22 HIP+T6 and QE22-T4 are two conditions of the same magnesium alloy grade, QE22: HIP+T6 versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. QE22 HIP+T6 is the stronger of the two: yield strength 200 MPa (29 ksi) against 115 MPa (16.7 ksi) for QE22-T4, about 74% more; tensile strength follows at 270 MPa (39.2 ksi) vs 220 MPa (31.9 ksi). In exchange, QE22-T4 is the more ductile: elongation 6% versus 5% for QE22 HIP+T6, and QE22 HIP+T6 is harder (80 HB vs 60 HB). QE22 HIP+T6 runs hotter in service (200°C vs 150°C continuous) and QE22 HIP+T6 conducts heat better (113 W/m·K vs 100 W/m·K).

QE22 HIP+T6Choose it when strength drives the design, or when the part sees heat.

QE22-T4Choose it when the part is bent, formed or impact-loaded.

QE22 HIP+T6 vs QE22-T4: properties

QE22 HIP+T6QE22-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
115 MPa16.7 ksi

Elongation at Break

5%
6%

Compressive Strength

195 MPa28.3 ksi
115 MPa16.7 ksi

Shear Strength

155 MPa22.5 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

19 MPa·√m17.3 ksi·√in
18 MPa·√m16.4 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

80 HB
60 HB

Hardness, Vickers

85 HV
63 HV

Same in both: Elastic (Young's) Modulus 44 GPa6.4 Msi · Shear Modulus 16.5 GPa2.4 Msi · Bulk Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 1.82 g/cm³0.07 lb/in³ · Melting Point (Solidus) 549°C1,020 °F · Liquidus Temperature 604°C1,119 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

113 W/m·K65.3 BTU/hr·ft·°F
100 W/m·K57.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 1,000 J/kg·K0.24 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 26.7 µm/m·K14.8 µin/in·°F · Latent Heat of Fusion 370 J/g159 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

24 % IACS
20 % IACS

Electrical Resistivity

7.2×10⁻⁸ Ω·m2.83 µΩ·in
8.6×10⁻⁸ Ω·m3.39 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
27 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -1.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

90 / 100
91 / 100

Machinability Rating (AISI 1212 = 100 %)

400%
405%

Weldability

55 / 100
60 / 100

Formability (cold)

10 / 100
14 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 380 MJ/kg163,371 BTU/lb · Embodied Carbon (primary production) 32 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every magnesium alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

701001502001.41.51.61.71.8Density (g/cm³)Yield strength (MPa) — log scaleQE22

QE22 HIP+T6 vs QE22-T4 — frequently asked

Is QE22 HIP+T6 stronger than QE22-T4?

Yes. QE22 HIP+T6 has a typical yield strength of 200 MPa (29 ksi) against 115 MPa (16.7 ksi) for QE22-T4 — about 74% more. Tensile strength is 270 MPa (39.2 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, HIP+T6 or T4?

T6 is the default QE22 condition in the FabDigit quote flow (neither HIP+T6 nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, QE22 HIP+T6 or QE22-T4?

QE22-T4. Its weldability rates good (60/100) against good (55/100) for QE22 HIP+T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in QE22 HIP+T6 and QE22-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.