FabDigitFabDigit

Alumina-Lime-Silica Glass (IEC G-400) ANN vs Alumina-Lime-Silica Glass (IEC G-400) TEMP

Glass · Alumina-Lime-Silica Glass (IEC G-400) temper comparison

Alumina-Lime-Silica Glass (IEC G-400) ANN and Alumina-Lime-Silica Glass (IEC G-400) TEMP are two conditions of the same glass grade, Alumina-Lime-Silica Glass (IEC G-400): ANN (annealed) versus TEMP (thermally tempered). The chemistry is identical, so every difference below comes from the condition. Alumina-Lime-Silica Glass (IEC G-400) TEMP is the stronger of the two: tensile strength 150 MPa (21.8 ksi) against 60 MPa (8.7 ksi) for Alumina-Lime-Silica Glass (IEC G-400) ANN, about 150% more. Alumina-Lime-Silica Glass (IEC G-400) TEMP runs hotter in service (750°C vs 650°C continuous).

Alumina-Lime-Silica Glass (IEC G-400) TEMPChoose it when strength drives the design, or when the part sees heat.

Alumina-Lime-Silica Glass (IEC G-400) ANN vs Alumina-Lime-Silica Glass (IEC G-400) TEMP: properties

Alumina-Lime-Silica Glass (IEC G-400) ANNAlumina-Lime-Silica Glass (IEC G-400) TEMP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

60 MPa8.7 ksi
150 MPa21.8 ksi

Flexural Strength

90 MPa13.1 ksi
230 MPa33.4 ksi

Shear Strength

55 MPa8 ksi
120 MPa17.4 ksi

Same in both: Elastic (Young's) Modulus 87 GPa12.6 Msi · Shear Modulus 35 GPa5.1 Msi · Bulk Modulus 57 GPa8.3 Msi · Poisson's Ratio 0.25 · Elongation at Break 0% · Compressive Strength 1,000 MPa145 ksi · Fracture Toughness (K_IC) 0.8 MPa·√m0.73 ksi·√in · Hardness, Vickers 620 HV · Hardness, Knoop 600 HK · Hardness, Mohs 6.5

Physical

Density and transition temperatures.

Same in both: Density 2.6 g/cm³0.09 lb/in³ · Refractive Index 1.53 · Light Transmission 90% · Porosity 0%

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

650°C1,202 °F
750°C1,382 °F

Same in both: Thermal Conductivity 1.2 W/m·K0.69 BTU/hr·ft·°F · Specific Heat Capacity 840 J/kg·K0.2 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 4.6 µm/m·K2.6 µin/in·°F · Min Service Temperature -190°C-310 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 30 kV/mm762 V/mil · Dielectric Constant (1 MHz) 6.3 · Dissipation Factor (1 MHz) 0.004 · Volume Resistivity 1×10¹⁵ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 90 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

12 / 100
5 / 100

Same in both: Polishability 96 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.6 kg CO₂/kg · Embodied Water 15 L/kg1.8 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every glass grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005002.533.5Density (g/cm³)Yield strength (MPa) — log scale

Alumina-Lime-Silica Glass (IEC G-400) ANN vs Alumina-Lime-Silica Glass (IEC G-400) TEMP — frequently asked

Is Alumina-Lime-Silica Glass (IEC G-400) TEMP stronger than Alumina-Lime-Silica Glass (IEC G-400) ANN?

Yes. Alumina-Lime-Silica Glass (IEC G-400) TEMP has a typical tensile strength of 150 MPa (21.8 ksi) against 60 MPa (8.7 ksi) for Alumina-Lime-Silica Glass (IEC G-400) ANN — about 150% more.

Which condition does FabDigit quote by default, ANN or TEMP?

ANN is the default Alumina-Lime-Silica Glass (IEC G-400) condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Alumina-Lime-Silica Glass (IEC G-400) ANN or Alumina-Lime-Silica Glass (IEC G-400) TEMP?

Alumina-Lime-Silica Glass (IEC G-400) ANN, by a small margin. Both rate not recommended for machinability — 12/100 against 5/100 for Alumina-Lime-Silica Glass (IEC G-400) TEMP.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Alumina-Lime-Silica Glass (IEC G-400) ANN and Alumina-Lime-Silica Glass (IEC G-400) TEMP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.