FabDigitFabDigit

Copper Alloy Cu-DHP-H01 vs Cu-DHP-H08

Copper Alloy · Cu-DHP temper comparison

Cu-DHP-H01 and Cu-DHP-H08 are two conditions of the same copper alloy grade, Cu-DHP: H01 (quarter hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. Cu-DHP-H08 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 190 MPa (27.6 ksi) for Cu-DHP-H01, about 79% more; tensile strength follows at 370 MPa (53.7 ksi) vs 250 MPa (36.3 ksi). In exchange, Cu-DHP-H01 is the more ductile: elongation 25% versus 4% for Cu-DHP-H08, and Cu-DHP-H08 is harder (100 HB vs 60 HB). Cu-DHP-H01 runs hotter in service (150°C vs 100°C continuous). On the shop floor, Cu-DHP-H08 machines more easily (fair vs poor) and Cu-DHP-H01 welds better (very good vs good).

Cu-DHP-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Cu-DHP-H08Choose it when strength drives the design, or when the part is machined in volume.

Cu-DHP-H01 vs Cu-DHP-H08: properties

Cu-DHP-H01Cu-DHP-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
370 MPa53.7 ksi

Yield Strength (0.2% offset)

190 MPa27.6 ksi
340 MPa49.3 ksi

Elongation at Break

25%
4%

Shear Strength

170 MPa24.7 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
125 MPa18.1 ksi

Hardness, Brinell

60 HB
100 HB

Hardness, Vickers

68 HV
112 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

343 W/m·K198 BTU/hr·ft·°F
331 W/m·K191 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
100°C212 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

83 % IACS
80 % IACS

Electrical Resistivity

2.08×10⁻⁸ Ω·m0.819 µΩ·in
2.16×10⁻⁸ Ω·m0.85 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Weldability

70 / 100
60 / 100

Formability (cold)

90 / 100
45 / 100

Same in both: Brazeability / Solderability 98 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCu-DHP

Cu-DHP-H01 vs Cu-DHP-H08 — frequently asked

Is Cu-DHP-H08 stronger than Cu-DHP-H01?

Yes. Cu-DHP-H08 has a typical yield strength of 340 MPa (49.3 ksi) against 190 MPa (27.6 ksi) for Cu-DHP-H01 — about 79% more. Tensile strength is 370 MPa (53.7 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, H01 or H08?

H58 is the default Cu-DHP condition in the FabDigit quote flow (neither H01 nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Cu-DHP-H01 or Cu-DHP-H08?

Cu-DHP-H08. Its machinability rates fair (35/100) against poor (25/100) for Cu-DHP-H01; for welding the order is Cu-DHP-H01 first (very good, 70/100) then Cu-DHP-H08 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Cu-DHP-H01 and Cu-DHP-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.