FabDigitFabDigit

Copper Alloy CC767S-GM vs CC767S-GS

Copper Alloy · CC767S temper comparison

CC767S-GM and CC767S-GS are two conditions of the same copper alloy grade, CC767S: GM (permanent (metal) mould cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC767S-GM is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 150 MPa (21.8 ksi) for CC767S-GS, about 20% more; tensile strength follows at 450 MPa (65.3 ksi) vs 400 MPa (58 ksi). In exchange, CC767S-GS is the more ductile: elongation 32% versus 22% for CC767S-GM, and CC767S-GM is harder (95 HB vs 80 HB).

CC767S-GMChoose it when strength drives the design.

CC767S-GSChoose it when the part is bent, formed or impact-loaded.

CC767S-GM vs CC767S-GS: properties

CC767S-GMCC767S-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
150 MPa21.8 ksi

Elongation at Break

22%
32%

Reduction in Area

22%
30%

Shear Strength

290 MPa42.1 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
32 J23.6 ft·lbf

Hardness, Brinell

95 HB
80 HB

Hardness, Rockwell B

50 HRB
40 HRB

Hardness, Vickers

100 HV
85 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 105 W/m·K60.7 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 20 % IACS · Electrical Resistivity 8.6×10⁻⁸ Ω·m3.39 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

22 / 100
25 / 100

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 130% · Weldability 40 / 100 · Castability 85 / 100 · Brazeability / Solderability 75 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 47 MJ/kg20,206 BTU/lb · Embodied Carbon (primary production) 3.1 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC767S

CC767S-GM vs CC767S-GS — frequently asked

Is CC767S-GM stronger than CC767S-GS?

Yes. CC767S-GM has a typical yield strength of 180 MPa (26.1 ksi) against 150 MPa (21.8 ksi) for CC767S-GS — about 20% more. Tensile strength is 450 MPa (65.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, GM or GS?

GS is the default CC767S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC767S-GM over CC767S-GS?

Pick CC767S-GM when strength drives the design. Pick CC767S-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC767S-GM and CC767S-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.