FabDigitFabDigit

Copper Alloy CC764S-GM vs CC764S-GS

Copper Alloy · CC764S temper comparison

CC764S-GM and CC764S-GS are two conditions of the same copper alloy grade, CC764S: GM (permanent (metal) mould / chill cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC764S-GM is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for CC764S-GS, about 15% more; tensile strength follows at 740 MPa (107 ksi) vs 680 MPa (98.6 ksi). In exchange, CC764S-GS is the more ductile: elongation 18% versus 15% for CC764S-GM, and CC764S-GM is harder (185 HB vs 170 HB).

CC764S-GMChoose it when strength drives the design.

CC764S-GSChoose it when the part is bent, formed or impact-loaded.

CC764S-GM vs CC764S-GS: properties

CC764S-GMCC764S-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
100 GPa14.5 Msi

Tensile Strength (Ultimate)

740 MPa107 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
390 MPa56.6 ksi

Elongation at Break

15%
18%

Reduction in Area

18%
22%

Compressive Strength

740 MPa107 ksi
700 MPa102 ksi

Shear Strength

455 MPa66 ksi
425 MPa61.6 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
180 MPa26.1 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

185 HB
170 HB

Hardness, Vickers

195 HV
180 HV

Same in both: Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 925°C1,697 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 32 W/m·K18.5 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

56 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

12 / 100
15 / 100

Same in both: Weldability 25 / 100 · Castability 75 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC764S

CC764S-GM vs CC764S-GS — frequently asked

Is CC764S-GM stronger than CC764S-GS?

Yes. CC764S-GM has a typical yield strength of 450 MPa (65.3 ksi) against 390 MPa (56.6 ksi) for CC764S-GS — about 15% more. Tensile strength is 740 MPa (107 ksi) vs 680 MPa (98.6 ksi).

Which condition does FabDigit quote by default, GM or GS?

GS is the default CC764S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC764S-GM over CC764S-GS?

Pick CC764S-GM when strength drives the design. Pick CC764S-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC764S-GM and CC764S-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.