FabDigitFabDigit

Copper Alloy CC762S-GC vs CC762S-GS

Copper Alloy · CC762S temper comparison

CC762S-GC and CC762S-GS are two conditions of the same copper alloy grade, CC762S: GC (continuous cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC762S-GC is the stronger of the two: yield strength 510 MPa (74 ksi) against 470 MPa (68.2 ksi) for CC762S-GS, about 9% more. In exchange, CC762S-GS is the more ductile: elongation 12% versus 10% for CC762S-GC, and CC762S-GC is harder (215 HB vs 200 HB).

CC762S-GCChoose it when strength drives the design.

CC762S-GSChoose it when the part is bent, formed or impact-loaded.

CC762S-GC vs CC762S-GS: properties

CC762S-GCCC762S-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
100 GPa14.5 Msi

Tensile Strength (Ultimate)

800 MPa116 ksi
780 MPa113 ksi

Yield Strength (0.2% offset)

510 MPa74 ksi
470 MPa68.2 ksi

Elongation at Break

10%
12%

Reduction in Area

13%
15%

Compressive Strength

525 MPa76.1 ksi
490 MPa71.1 ksi

Shear Strength

485 MPa70.3 ksi
470 MPa68.2 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

215 HB
200 HB

Hardness, Rockwell B

94 HRB
92 HRB

Hardness, Vickers

225 HV
210 HV

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 100 GPa14.5 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 870°C1,598 °F · Liquidus Temperature 920°C1,688 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 36 W/m·K20.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

11 / 100
12 / 100

Same in both: Machinability 26 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 28 / 100 · Castability 72 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC762S

CC762S-GC vs CC762S-GS — frequently asked

Is CC762S-GC stronger than CC762S-GS?

Yes. CC762S-GC has a typical yield strength of 510 MPa (74 ksi) against 470 MPa (68.2 ksi) for CC762S-GS — about 9% more. Tensile strength is 800 MPa (116 ksi) vs 780 MPa (113 ksi).

Which condition does FabDigit quote by default, GC or GS?

GS is the default CC762S condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC762S-GC over CC762S-GS?

Pick CC762S-GC when strength drives the design. Pick CC762S-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC762S-GC and CC762S-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.