FabDigitFabDigit

Copper Alloy CC754S-GC vs CC754S-GS

Copper Alloy · CC754S temper comparison

CC754S-GC and CC754S-GS are two conditions of the same copper alloy grade, CC754S: GC (continuous cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC754S-GC is the stronger of the two: yield strength 160 MPa (23.2 ksi) against 120 MPa (17.4 ksi) for CC754S-GS, about 33% more; tensile strength follows at 380 MPa (55.1 ksi) vs 300 MPa (43.5 ksi). In exchange, CC754S-GS is the more ductile: elongation 22% versus 18% for CC754S-GC, and CC754S-GC is harder (95 HB vs 80 HB). CC754S-GC is stiffer (97 GPa vs 90 GPa).

CC754S-GCChoose it when strength drives the design.

CC754S-GSChoose it when the part is bent, formed or impact-loaded.

CC754S-GC vs CC754S-GS: properties

CC754S-GCCC754S-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

97 GPa14.1 Msi
90 GPa13.1 Msi

Tensile Strength (Ultimate)

380 MPa55.1 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

160 MPa23.2 ksi
120 MPa17.4 ksi

Elongation at Break

18%
22%

Reduction in Area

16%
20%

Shear Strength

232 MPa33.6 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

34 MPa·√m30.9 ksi·√in
28 MPa·√m25.5 ksi·√in

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

95 HB
80 HB

Hardness, Rockwell B

55 HRB
42 HRB

Hardness, Vickers

100 HV
84 HV

Same in both: Shear Modulus 36 GPa5.2 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.4 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

116 W/m·K67 BTU/hr·ft·°F
112 W/m·K64.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
24 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

205%
200%

Formability (cold)

24 / 100
20 / 100

Same in both: Weldability 25 / 100 · Castability 85 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC754S

CC754S-GC vs CC754S-GS — frequently asked

Is CC754S-GC stronger than CC754S-GS?

Yes. CC754S-GC has a typical yield strength of 160 MPa (23.2 ksi) against 120 MPa (17.4 ksi) for CC754S-GS — about 33% more. Tensile strength is 380 MPa (55.1 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, GC or GS?

GM is the default CC754S condition in the FabDigit quote flow (neither GC nor GS). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC754S-GC over CC754S-GS?

Pick CC754S-GC when strength drives the design. Pick CC754S-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC754S-GC and CC754S-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.