FabDigitFabDigit

Copper Alloy CC751S-GC vs CC751S-GZ

Copper Alloy · CC751S temper comparison

CC751S-GC and CC751S-GZ are two conditions of the same copper alloy grade, CC751S: GC (continuously cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC751S-GC is the stronger of the two: yield strength 120 MPa (17.4 ksi) against 110 MPa (16 ksi) for CC751S-GZ, about 9% more. CC751S-GC is harder — 70 HB against 65 HB for CC751S-GZ — which matters for wear surfaces and threads.

CC751S-GCChoose it when strength drives the design, or when surface hardness matters.

CC751S-GC vs CC751S-GZ: properties

CC751S-GCCC751S-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

93 GPa13.5 Msi
92 GPa13.3 Msi

Tensile Strength (Ultimate)

280 MPa40.6 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
110 MPa16 ksi

Reduction in Area

14%
15%

Compressive Strength

350 MPa50.8 ksi
340 MPa49.3 ksi

Shear Strength

205 MPa29.7 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
80 MPa11.6 ksi

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

70 HB
65 HB

Hardness, Rockwell B

37 HRB
32 HRB

Hardness, Vickers

74 HV
68 HV

Same in both: Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.35 · Elongation at Break 12%

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 940°C1,724 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 110 W/m·K63.6 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 20 % IACS · Electrical Resistivity 8.6×10⁻⁸ Ω·m3.39 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

86 / 100
82 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
80%

Formability (cold)

20 / 100
22 / 100

Same in both: Weldability 20 / 100 · Castability 88 / 100 · Brazeability / Solderability 75 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC751S

CC751S-GC vs CC751S-GZ — frequently asked

Is CC751S-GC stronger than CC751S-GZ?

Yes. CC751S-GC has a typical yield strength of 120 MPa (17.4 ksi) against 110 MPa (16 ksi) for CC751S-GZ — about 9% more. Tensile strength is 280 MPa (40.6 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, GC or GZ?

GS is the default CC751S condition in the FabDigit quote flow (neither GC nor GZ). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC751S-GC over CC751S-GZ?

Pick CC751S-GC when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC751S-GC and CC751S-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.