FabDigitFabDigit

Copper Alloy CC497K-GC vs CC497K-GS

Copper Alloy · CC497K temper comparison

CC497K-GC and CC497K-GS are two conditions of the same copper alloy grade, CC497K: GC (continuously cast bar/tube) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC497K-GC is the stronger of the two: yield strength 85 MPa (12.3 ksi) against 70 MPa (10.2 ksi) for CC497K-GS, about 21% more; tensile strength follows at 195 MPa (28.3 ksi) vs 165 MPa (23.9 ksi). CC497K-GC is the more ductile: elongation 9% versus 8% for CC497K-GS, and CC497K-GC is harder (52 HB vs 47 HB). CC497K-GC is stiffer (72 GPa vs 68 GPa).

CC497K-GCChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

CC497K-GC vs CC497K-GS: properties

CC497K-GCCC497K-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72 GPa10.4 Msi
68 GPa9.9 Msi

Tensile Strength (Ultimate)

195 MPa28.3 ksi
165 MPa23.9 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
70 MPa10.2 ksi

Elongation at Break

9%
8%

Reduction in Area

10%
8%

Compressive Strength

245 MPa35.5 ksi
200 MPa29 ksi

Shear Strength

135 MPa19.6 ksi
120 MPa17.4 ksi

Fatigue Strength (Endurance Limit)

58 MPa8.4 ksi
50 MPa7.3 ksi

Charpy V-Notch Impact (RT)

9 J6.6 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

52 HB
47 HB

Hardness, Vickers

55 HV
50 HV

Same in both: Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 90 GPa13.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 9.3 g/cm³0.34 lb/in³ · Melting Point (Solidus) 762°C1,404 °F · Liquidus Temperature 940°C1,724 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
47 W/m·K27.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11.5 % IACS
10.5 % IACS

Electrical Resistivity

1.5×10⁻⁷ Ω·m5.91 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

92 / 100
90 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
80%

Same in both: Weldability 10 / 100 · Formability (cold) 10 / 100 · Castability 75 / 100 · Brazeability / Solderability 45 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC497K

CC497K-GC vs CC497K-GS — frequently asked

Is CC497K-GC stronger than CC497K-GS?

Yes. CC497K-GC has a typical yield strength of 85 MPa (12.3 ksi) against 70 MPa (10.2 ksi) for CC497K-GS — about 21% more. Tensile strength is 195 MPa (28.3 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, GC or GS?

GC is the default CC497K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC497K-GC over CC497K-GS?

Pick CC497K-GC when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC497K-GC and CC497K-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.