FabDigitFabDigit

Copper Alloy CC483K-GC vs CC483K-GM

Copper Alloy · CC483K temper comparison

CC483K-GC and CC483K-GM are two conditions of the same copper alloy grade, CC483K: GC (continuously cast) versus GM (permanent mould (chill) cast). The chemistry is identical, so every difference below comes from the condition. CC483K-GC is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 175 MPa (25.4 ksi) for CC483K-GM, about 9% more; tensile strength follows at 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi). CC483K-GC is harder — 100 HB against 95 HB for CC483K-GM — which matters for wear surfaces and threads.

CC483K-GCChoose it when strength drives the design, or when surface hardness matters.

CC483K-GC vs CC483K-GM: properties

CC483K-GCCC483K-GM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

100 GPa14.5 Msi
98 GPa14.2 Msi

Tensile Strength (Ultimate)

320 MPa46.4 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

190 MPa27.6 ksi
175 MPa25.4 ksi

Reduction in Area

8%
7%

Compressive Strength

620 MPa89.9 ksi
580 MPa84.1 ksi

Shear Strength

205 MPa29.7 ksi
192 MPa27.8 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
100 MPa14.5 ksi

Hardness, Brinell

100 HB
95 HB

Hardness, Rockwell B

58 HRB
54 HRB

Hardness, Vickers

105 HV
100 HV

Same in both: Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Elongation at Break 6% · Charpy V-Notch Impact (RT) 7 J5.2 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 830°C1,526 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 48 W/m·K27.7 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -180°C-292 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
20%

Same in both: Weldability 25 / 100 · Formability (cold) 10 / 100 · Castability 75 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC483K

CC483K-GC vs CC483K-GM — frequently asked

Is CC483K-GC stronger than CC483K-GM?

Yes. CC483K-GC has a typical yield strength of 190 MPa (27.6 ksi) against 175 MPa (25.4 ksi) for CC483K-GM — about 9% more. Tensile strength is 320 MPa (46.4 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, GC or GM?

GC is the default CC483K condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC483K-GC over CC483K-GM?

Pick CC483K-GC when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC483K-GC and CC483K-GM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.