FabDigitFabDigit

Copper Alloy CC381H-GS vs CC381H-GZ

Copper Alloy · CC381H temper comparison

CC381H-GS and CC381H-GZ are two conditions of the same copper alloy grade, CC381H: GS (sand cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC381H-GZ is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 255 MPa (37 ksi) for CC381H-GS, about 8% more; tensile strength follows at 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi). In exchange, CC381H-GS is the more ductile: elongation 25% versus 20% for CC381H-GZ, and CC381H-GZ is harder (150 HB vs 140 HB).

CC381H-GSChoose it when the part is bent, formed or impact-loaded.

CC381H-GZChoose it when strength drives the design.

CC381H-GS vs CC381H-GZ: properties

CC381H-GSCC381H-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

150 GPa21.8 Msi
152 GPa22 Msi

Tensile Strength (Ultimate)

470 MPa68.2 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
275 MPa39.9 ksi

Elongation at Break

25%
20%

Reduction in Area

25%
20%

Shear Strength

290 MPa42.1 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
165 MPa23.9 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

140 HB
150 HB

Hardness, Rockwell B

76 HRB
80 HRB

Same in both: Shear Modulus 56 GPa8.1 Msi · Bulk Modulus 145 GPa21 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 28 W/m·K16.2 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.3 µm/m·K8.5 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.6 % IACS · Electrical Resistivity 3.75×10⁻⁷ Ω·m14.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
82 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
42%

Weldability

75 / 100
76 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 70 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC381H

CC381H-GS vs CC381H-GZ — frequently asked

Is CC381H-GZ stronger than CC381H-GS?

Yes. CC381H-GZ has a typical yield strength of 275 MPa (39.9 ksi) against 255 MPa (37 ksi) for CC381H-GS — about 8% more. Tensile strength is 500 MPa (72.5 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GS is the default CC381H condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC381H-GS over CC381H-GZ?

Pick CC381H-GS when the part is bent, formed or impact-loaded. Pick CC381H-GZ when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC381H-GS and CC381H-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.