FabDigitFabDigit

Copper Alloy CC334G-GC vs CC334G-GM

Copper Alloy · CC334G temper comparison

CC334G-GC and CC334G-GM are two conditions of the same copper alloy grade, CC334G: GC (continuously cast bar/tube) versus GM (chill / permanent-mould cast). The chemistry is identical, so every difference below comes from the condition. CC334G-GM is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 470 MPa (68.2 ksi) for CC334G-GC, about 6% more. CC334G-GM is harder — 27 HRC against 25 HRC for CC334G-GC — which matters for wear surfaces and threads.

CC334G-GMChoose it when strength drives the design, or when surface hardness matters.

CC334G-GC vs CC334G-GM: properties

CC334G-GCCC334G-GM

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

122 GPa17.7 Msi
124 GPa18 Msi

Tensile Strength (Ultimate)

740 MPa107 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
500 MPa72.5 ksi

Compressive Strength

1,040 MPa151 ksi
1,080 MPa157 ksi

Shear Strength

445 MPa64.5 ksi
455 MPa66 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
255 MPa37 ksi

Fracture Toughness (K_IC)

25 MPa·√m22.8 ksi·√in
24 MPa·√m21.8 ksi·√in

Hardness, Brinell

260 HB
270 HB

Hardness, Rockwell B

103 HRB
105 HRB

Hardness, Rockwell C

25 HRC
27 HRC

Hardness, Vickers

272 HV
284 HV

Same in both: Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 113 GPa16.4 Msi · Poisson's Ratio 0.32 · Elongation at Break 5% · Reduction in Area 6% · Charpy V-Notch Impact (RT) 9 J6.6 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 7.45 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 38 W/m·K22 BTU/hr·ft·°F · Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16 µm/m·K8.9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.46×10⁻⁷ Ω·m9.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
18%

Weldability

40 / 100
38 / 100

Formability (cold)

5 / 100
4 / 100

Same in both: Castability 65 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC334G

CC334G-GC vs CC334G-GM — frequently asked

Is CC334G-GM stronger than CC334G-GC?

Yes. CC334G-GM has a typical yield strength of 500 MPa (72.5 ksi) against 470 MPa (68.2 ksi) for CC334G-GC — about 6% more. Tensile strength is 760 MPa (110 ksi) vs 740 MPa (107 ksi).

Which condition does FabDigit quote by default, GC or GM?

GS is the default CC334G condition in the FabDigit quote flow (neither GC nor GM). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC334G-GC over CC334G-GM?

Pick CC334G-GM when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC334G-GC and CC334G-GM side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.