FabDigitFabDigit

Copper Alloy CC330G-GS vs CC330G-GZ

Copper Alloy · CC330G temper comparison

CC330G-GS and CC330G-GZ are two conditions of the same copper alloy grade, CC330G: GS (sand cast) versus GZ (centrifugally cast). The chemistry is identical, so every difference below comes from the condition. CC330G-GZ is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 200 MPa (29 ksi) for CC330G-GS, about 10% more; tensile strength follows at 550 MPa (79.8 ksi) vs 500 MPa (72.5 ksi). CC330G-GZ is harder — 120 HB against 110 HB for CC330G-GS — which matters for wear surfaces and threads.

CC330G-GZChoose it when strength drives the design, or when surface hardness matters.

CC330G-GS vs CC330G-GZ: properties

CC330G-GSCC330G-GZ

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

112 GPa16.2 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

500 MPa72.5 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
220 MPa31.9 ksi

Reduction in Area

22%
26%

Compressive Strength

210 MPa30.5 ksi
230 MPa33.4 ksi

Shear Strength

300 MPa43.5 ksi
325 MPa47.1 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
185 MPa26.8 ksi

Fracture Toughness (K_IC)

44 MPa·√m40 ksi·√in
47 MPa·√m42.8 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

110 HB
120 HB

Hardness, Rockwell B

62 HRB
69 HRB

Hardness, Vickers

115 HV
126 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.33 · Elongation at Break 25%

Physical

Density and transition temperatures.

Same in both: Density 7.6 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,050°C1,922 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 59 W/m·K34.1 BTU/hr·ft·°F · Specific Heat Capacity 400 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 13 % IACS · Electrical Resistivity 1.33×10⁻⁷ Ω·m5.24 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
41 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
44%

Weldability

78 / 100
76 / 100

Formability (cold)

25 / 100
24 / 100

Same in both: Castability 68 / 100 · Brazeability / Solderability 30 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC330G

CC330G-GS vs CC330G-GZ — frequently asked

Is CC330G-GZ stronger than CC330G-GS?

Yes. CC330G-GZ has a typical yield strength of 220 MPa (31.9 ksi) against 200 MPa (29 ksi) for CC330G-GS — about 10% more. Tensile strength is 550 MPa (79.8 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, GS or GZ?

GS is the default CC330G condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC330G-GS over CC330G-GZ?

Pick CC330G-GZ when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC330G-GS and CC330G-GZ side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.