FabDigitFabDigit

Copper Alloy C99750 M-AC vs C99750-TF00

Copper Alloy · C99750 temper comparison

C99750 M-AC and C99750-TF00 are two conditions of the same copper alloy grade, C99750: M-AC (as Cast) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C99750-TF00 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 234 MPa (33.9 ksi) for C99750 M-AC, about 77% more; tensile strength follows at 620 MPa (89.9 ksi) vs 455 MPa (66 ksi). In exchange, C99750 M-AC is the more ductile: elongation 25% versus 10% for C99750-TF00, and C99750-TF00 is harder (200 HB vs 130 HB). C99750 M-AC runs hotter in service (250°C vs 200°C continuous) and C99750-TF00 conducts electricity better (4.5 % IACS vs 3.5 % IACS). On the shop floor, C99750-TF00 machines more easily (45 vs 35 out of 100) and C99750 M-AC welds better (fair vs poor).

C99750 M-ACChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C99750-TF00Choose it when strength drives the design, or when the part is machined in volume.

C99750 M-AC vs C99750-TF00: properties

C99750 M-ACC99750-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

100 GPa14.5 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

455 MPa66 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

234 MPa33.9 ksi
415 MPa60.2 ksi

Elongation at Break

25%
10%

Shear Strength

310 MPa45 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
210 MPa30.5 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

130 HB
200 HB

Hardness, Rockwell B

74 HRB
94 HRB

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 7.78 g/cm³0.28 lb/in³ · Melting Point (Solidus) 871°C1,600 °F · Liquidus Temperature 899°C1,650 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

25 W/m·K14.4 BTU/hr·ft·°F
27 W/m·K15.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Same in both: Specific Heat Capacity 400 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.5 % IACS
4.5 % IACS

Same in both: Electrical Resistivity 4.9×10⁻⁷ Ω·m19.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
40%

Weldability

45 / 100
25 / 100

Same in both: Formability (cold) 25 / 100 · Castability 75 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC99750

C99750 M-AC vs C99750-TF00 — frequently asked

Is C99750-TF00 stronger than C99750 M-AC?

Yes. C99750-TF00 has a typical yield strength of 415 MPa (60.2 ksi) against 234 MPa (33.9 ksi) for C99750 M-AC — about 77% more. Tensile strength is 620 MPa (89.9 ksi) vs 455 MPa (66 ksi).

Which condition does FabDigit quote by default, M-AC or TF00?

M-AC is the default C99750 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C99750 M-AC or C99750-TF00?

C99750-TF00, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for C99750 M-AC; for welding the order is C99750 M-AC first (fair, 45/100) then C99750-TF00 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C99750 M-AC and C99750-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.