FabDigitFabDigit

Copper Alloy C99700-M01 vs C99700-M02

Copper Alloy · C99700 temper comparison

C99700-M01 and C99700-M02 are two conditions of the same copper alloy grade, C99700: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C99700-M02 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 230 MPa (33.4 ksi) for C99700-M01, about 20% more; tensile strength follows at 485 MPa (70.3 ksi) vs 450 MPa (65.3 ksi). In exchange, C99700-M01 is the more ductile: elongation 25% versus 20% for C99700-M02, and C99700-M02 is harder (145 HB vs 125 HB).

C99700-M01Choose it when the part is bent, formed or impact-loaded.

C99700-M02Choose it when strength drives the design.

C99700-M01 vs C99700-M02: properties

C99700-M01C99700-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
485 MPa70.3 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
275 MPa39.9 ksi

Elongation at Break

25%
20%

Reduction in Area

22%
18%

Shear Strength

290 MPa42.1 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

125 HB
145 HB

Hardness, Rockwell B

75 HRB
80 HRB

Hardness, Vickers

132 HV
152 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.03 g/cm³0.29 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 905°C1,661 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 27 W/m·K15.6 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3 % IACS · Electrical Resistivity 5.7×10⁻⁷ Ω·m22.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
28%

Formability (cold)

18 / 100
15 / 100

Same in both: Weldability 35 / 100 · Castability 80 / 100 · Brazeability / Solderability 55 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC99700

C99700-M01 vs C99700-M02 — frequently asked

Is C99700-M02 stronger than C99700-M01?

Yes. C99700-M02 has a typical yield strength of 275 MPa (39.9 ksi) against 230 MPa (33.4 ksi) for C99700-M01 — about 20% more. Tensile strength is 485 MPa (70.3 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C99700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C99700-M01 over C99700-M02?

Pick C99700-M01 when the part is bent, formed or impact-loaded. Pick C99700-M02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C99700-M01 and C99700-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.