FabDigitFabDigit

Copper Alloy C97300-M03 vs C97300-M05

Copper Alloy · C97300 temper comparison

C97300-M03 and C97300-M05 are two conditions of the same copper alloy grade, C97300: M03 (as chill cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C97300-M03 is the stronger of the two: yield strength 128 MPa (18.6 ksi) against 117 MPa (17 ksi) for C97300-M05, about 9% more; tensile strength follows at 255 MPa (37 ksi) vs 235 MPa (34.1 ksi). C97300-M03 is harder — 60 HB against 55 HB for C97300-M05 — which matters for wear surfaces and threads.

C97300-M03Choose it when strength drives the design, or when surface hardness matters.

C97300-M03 vs C97300-M05: properties

C97300-M03C97300-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

128 MPa18.6 ksi
117 MPa17 ksi

Elongation at Break

16%
15%

Reduction in Area

15%
14%

Shear Strength

176 MPa25.5 ksi
162 MPa23.5 ksi

Fatigue Strength (Endurance Limit)

93 MPa13.5 ksi
88 MPa12.8 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

60 HB
55 HB

Hardness, Vickers

63 HV
58 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.95 g/cm³0.32 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 1,040°C1,904 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6 % IACS · Electrical Resistivity 2.87×10⁻⁷ Ω·m11.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

63 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 78 / 100 · Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 15 / 100 · Formability (cold) 8 / 100 · Castability 85 / 100 · Brazeability / Solderability 70 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 340 L/kg40.7 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC97300

C97300-M03 vs C97300-M05 — frequently asked

Is C97300-M03 stronger than C97300-M05?

Yes. C97300-M03 has a typical yield strength of 128 MPa (18.6 ksi) against 117 MPa (17 ksi) for C97300-M05 — about 9% more. Tensile strength is 255 MPa (37 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, M03 or M05?

M01 is the default C97300 condition in the FabDigit quote flow (neither M03 nor M05). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C97300-M03 over C97300-M05?

Pick C97300-M03 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C97300-M03 and C97300-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.