FabDigitFabDigit

Copper Alloy C97300-M01 vs C97300-M02

Copper Alloy · C97300 temper comparison

C97300-M01 and C97300-M02 are two conditions of the same copper alloy grade, C97300: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C97300-M02 is the stronger of the two: yield strength 125 MPa (18.1 ksi) against 117 MPa (17 ksi) for C97300-M01, about 7% more. In exchange, C97300-M01 is the more ductile: elongation 18% versus 16% for C97300-M02, and C97300-M02 is harder (58 HB vs 55 HB).

C97300-M01Choose it when the part is bent, formed or impact-loaded.

C97300-M02Choose it when strength drives the design.

C97300-M01 vs C97300-M02: properties

C97300-M01C97300-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

117 MPa17 ksi
125 MPa18.1 ksi

Elongation at Break

18%
16%

Reduction in Area

16%
15%

Shear Strength

165 MPa23.9 ksi
172 MPa24.9 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
92 MPa13.3 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
13 J9.6 ft·lbf

Hardness, Brinell

55 HB
58 HB

Hardness, Vickers

58 HV
61 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.95 g/cm³0.32 lb/in³ · Melting Point (Solidus) 880°C1,616 °F · Liquidus Temperature 1,040°C1,904 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6 % IACS · Electrical Resistivity 2.87×10⁻⁷ Ω·m11.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 78 / 100 · Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 15 / 100 · Formability (cold) 8 / 100 · Castability 85 / 100 · Brazeability / Solderability 70 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 340 L/kg40.7 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC97300

C97300-M01 vs C97300-M02 — frequently asked

Is C97300-M02 stronger than C97300-M01?

Yes. C97300-M02 has a typical yield strength of 125 MPa (18.1 ksi) against 117 MPa (17 ksi) for C97300-M01 — about 7% more. Tensile strength is 250 MPa (36.3 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C97300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C97300-M01 over C97300-M02?

Pick C97300-M01 when the part is bent, formed or impact-loaded. Pick C97300-M02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C97300-M01 and C97300-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.