FabDigitFabDigit

Copper Alloy C95300-M01 vs C95300-M07

Copper Alloy · C95300 temper comparison

C95300-M01 and C95300-M07 are two conditions of the same copper alloy grade, C95300: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C95300-M07 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 170 MPa (24.7 ksi) for C95300-M01, about 15% more; tensile strength follows at 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi). In exchange, C95300-M01 is the more ductile: elongation 25% versus 22% for C95300-M07, and C95300-M07 is harder (120 HB vs 110 HB).

C95300-M01Choose it when the part is bent, formed or impact-loaded.

C95300-M07Choose it when strength drives the design.

C95300-M01 vs C95300-M07: properties

C95300-M01C95300-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
195 MPa28.3 ksi

Elongation at Break

25%
22%

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
165 MPa23.9 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
28 J20.7 ft·lbf

Hardness, Brinell

110 HB
120 HB

Hardness, Rockwell B

62 HRB
68 HRB

Hardness, Vickers

115 HV
126 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.32 · Compressive Strength 180 MPa26.1 ksi · Shear Strength 330 MPa47.9 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.53 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,040°C1,904 °F · Liquidus Temperature 1,045°C1,913 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 58.6 W/m·K33.9 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 13 % IACS · Electrical Resistivity 1.33×10⁻⁷ Ω·m5.24 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 48 / 100 · Machinability Rating (AISI 1212 = 100 %) 55% · Weldability 70 / 100 · Formability (cold) 15 / 100 · Castability 75 / 100 · Brazeability / Solderability 30 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 50 MJ/kg21,496 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC95300

C95300-M01 vs C95300-M07 — frequently asked

Is C95300-M07 stronger than C95300-M01?

Yes. C95300-M07 has a typical yield strength of 195 MPa (28.3 ksi) against 170 MPa (24.7 ksi) for C95300-M01 — about 15% more. Tensile strength is 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M01 is the default C95300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C95300-M01 over C95300-M07?

Pick C95300-M01 when the part is bent, formed or impact-loaded. Pick C95300-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C95300-M01 and C95300-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.