FabDigitFabDigit

Copper Alloy C92900-M01 vs C92900-M07

Copper Alloy · C92900 temper comparison

C92900-M01 and C92900-M07 are two conditions of the same copper alloy grade, C92900: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C92900-M07 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 180 MPa (26.1 ksi) for C92900-M01, about 22% more; tensile strength follows at 345 MPa (50 ksi) vs 325 MPa (47.1 ksi). C92900-M07 is the more ductile: elongation 10% versus 8% for C92900-M01, and C92900-M07 is harder (60 HRB vs 56 HRB).

C92900-M07Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C92900-M01 vs C92900-M07: properties

C92900-M01C92900-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
107 GPa15.5 Msi

Tensile Strength (Ultimate)

325 MPa47.1 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
220 MPa31.9 ksi

Elongation at Break

8%
10%

Reduction in Area

9%
12%

Compressive Strength

385 MPa55.8 ksi
410 MPa59.5 ksi

Shear Strength

235 MPa34.1 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
115 MPa16.7 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

100 HB
105 HB

Hardness, Rockwell B

56 HRB
60 HRB

Hardness, Vickers

105 HV
110 HV

Same in both: Shear Modulus 40 GPa5.8 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -150°C-238 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.72×10⁻⁷ Ω·m6.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 75 / 100 · Machinability Rating (AISI 1212 = 100 %) 240% · Weldability 20 / 100 · Formability (cold) 5 / 100 · Castability 80 / 100 · Brazeability / Solderability 65 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 240 L/kg28.8 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC92900

C92900-M01 vs C92900-M07 — frequently asked

Is C92900-M07 stronger than C92900-M01?

Yes. C92900-M07 has a typical yield strength of 220 MPa (31.9 ksi) against 180 MPa (26.1 ksi) for C92900-M01 — about 22% more. Tensile strength is 345 MPa (50 ksi) vs 325 MPa (47.1 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M07 is the default C92900 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C92900-M01 over C92900-M07?

Pick C92900-M07 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C92900-M01 and C92900-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.