FabDigitFabDigit

Copper Alloy C91700-M01 vs C91700-M05

Copper Alloy · C91700 temper comparison

C91700-M01 and C91700-M05 are two conditions of the same copper alloy grade, C91700: M01 (as sand cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C91700-M05 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 172 MPa (24.9 ksi) for C91700-M01, about 10% more. In exchange, C91700-M01 is the more ductile: elongation 12% versus 10% for C91700-M05, and C91700-M05 is harder (100 HB vs 95 HB).

C91700-M01Choose it when the part is bent, formed or impact-loaded.

C91700-M05Choose it when strength drives the design.

C91700-M01 vs C91700-M05: properties

C91700-M01C91700-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

105 GPa15.2 Msi
110 GPa16 Msi

Tensile Strength (Ultimate)

310 MPa45 ksi
325 MPa47.1 ksi

Yield Strength (0.2% offset)

172 MPa24.9 ksi
190 MPa27.6 ksi

Elongation at Break

12%
10%

Reduction in Area

10%
9%

Compressive Strength

480 MPa69.6 ksi
495 MPa71.8 ksi

Shear Strength

215 MPa31.2 ksi
225 MPa32.6 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
110 MPa16 ksi

Hardness, Brinell

95 HB
100 HB

Hardness, Rockwell B

56 HRB
60 HRB

Hardness, Vickers

100 HV
105 HV

Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 9 J6.6 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 35 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 25 / 100 · Castability 75 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC91700

C91700-M01 vs C91700-M05 — frequently asked

Is C91700-M05 stronger than C91700-M01?

Yes. C91700-M05 has a typical yield strength of 190 MPa (27.6 ksi) against 172 MPa (24.9 ksi) for C91700-M01 — about 10% more. Tensile strength is 325 MPa (47.1 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, M01 or M05?

M01 is the default C91700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C91700-M01 over C91700-M05?

Pick C91700-M01 when the part is bent, formed or impact-loaded. Pick C91700-M05 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C91700-M01 and C91700-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.