FabDigitFabDigit

Copper Alloy C91600-M01 vs C91600-M04

Copper Alloy · C91600 temper comparison

C91600-M01 and C91600-M04 are two conditions of the same copper alloy grade, C91600: M01 (as sand cast) versus M04 (as pressure die cast). The chemistry is identical, so every difference below comes from the condition. C91600-M04 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 152 MPa (22 ksi) for C91600-M01, about 25% more; tensile strength follows at 330 MPa (47.9 ksi) vs 310 MPa (45 ksi). In exchange, C91600-M01 is the more ductile: elongation 16% versus 10% for C91600-M04, and C91600-M04 is harder (115 HB vs 90 HB).

C91600-M01Choose it when the part is bent, formed or impact-loaded.

C91600-M04Choose it when strength drives the design.

C91600-M01 vs C91600-M04: properties

C91600-M01C91600-M04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

108 GPa15.7 Msi
112 GPa16.2 Msi

Tensile Strength (Ultimate)

310 MPa45 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

152 MPa22 ksi
190 MPa27.6 ksi

Elongation at Break

16%
10%

Reduction in Area

18%
11%

Compressive Strength

440 MPa63.8 ksi
510 MPa74 ksi

Shear Strength

210 MPa30.5 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
115 MPa16.7 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

90 HB
115 HB

Hardness, Rockwell B

48 HRB
65 HRB

Hardness, Vickers

95 HV
122 HV

Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

64 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
28%

Formability (cold)

8 / 100
7 / 100

Same in both: Weldability 20 / 100 · Castability 75 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC91600

C91600-M01 vs C91600-M04 — frequently asked

Is C91600-M04 stronger than C91600-M01?

Yes. C91600-M04 has a typical yield strength of 190 MPa (27.6 ksi) against 152 MPa (22 ksi) for C91600-M01 — about 25% more. Tensile strength is 330 MPa (47.9 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, M01 or M04?

M07 is the default C91600 condition in the FabDigit quote flow (neither M01 nor M04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C91600-M01 over C91600-M04?

Pick C91600-M01 when the part is bent, formed or impact-loaded. Pick C91600-M04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C91600-M01 and C91600-M04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.